4.1.3 Setting the transport carriage stop

Fig. 65: Setting the transport carriage stop
(1) - Reference switch
(2) - Switching screw
Proper setting
The stop (4) is at a distance of 2 mm from the transport carriage (3).
To set the stop for the transport carriage:
1. Slide the transport carriage (3) back until the surface of the switching
2. Loosen the counternut on the stop (4).
3. Move the stop (4) up to the transport carriage until it is at a distance
4. Tighten the counternut on the stop (4).
76
screw (2) is positioned at the center below the reference switch (1).
of 2 mm.
(3) - Transport carriage
(4) - Stop