Table of Contents

Advertisement

Quick Links

A+ Server
AS -2115GT-HNTR
USER'S MANUAL
Revision 1.0a

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro A+ Server AS-2115GT-HNTR

  • Page 1 A+ Server AS -2115GT-HNTR USER’S MANUAL Revision 1.0a...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Preface Contents Contacting Supermicro ......................7 Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System ......................8 1.3 System Features ........................9 1.4 Chassis Features .......................10 Control Panel ........................10 System: Front View ......................11 System: Rear View ......................12 1.5 Motherboard Layout ......................13 Quick Reference Table ......................14 Block Diagram ........................15...
  • Page 5 Preface Chapter 3 Maintenance and Component Installation 3.1 Removing Power ........................22 3.2 Accessing the System ......................23 Installing and Removing the Node Drawers ..............23 Removing Nodes from the Chassis ..................24 Removing the Chassis Cover ..................25 3.3 Static-Sensitive Devices .....................26 Precautions ........................26 Unpacking .........................26 3.4 Processor and Heatsink Installation ...................27 3.5 Memory ..........................35...
  • Page 6 Preface Chapter 4 Motherboard Connections 4.1 Power Connections ......................50 4.2 Headers and Connectors ....................51 4.3 Jumper Settings .........................52 How Jumpers Work ......................52 4.4 LED Indicators ........................54 Chapter 5 Software 5.1 Microsoft Windows OS Installation ..................55 5.2 Driver Installation ........................57 5.3 SuperDoctor®5 ........................58 5.4 IPMI ............................59 BMC ADMIN User Password ....................59 Appendix A Standardized Warning Statements for AC Systems...
  • Page 7: Contacting Supermicro

    San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 8: Overview

    A+ Server AS -2115GT-HNTR User's Manual Chapter 1 Introduction 1.1 Overview This chapter provides an outline of the functions and features of the AS -2115GT-HNTR A+ server. It is based on the H13SST-G motherboard and the CSE-GT214BC-R2K21BP chassis. In addition to the motherboard and chassis, several important parts that are included with the system are listed below.
  • Page 9: System Features

    Chapter 1: Introduction 1.3 System Features The following table provides you with an overview of the main features of the AS -2115GT-HNTR. Please refer to Appendix B for additional specifications. System Features Motherboard (per node) H13SST-G Chassis CSE-GT214BC-R2K21BP AMD EPYC 9004 series processors in Socket SP5 Management Chipset System on Chip (SoC)
  • Page 10: Chassis Features

    A+ Server AS -2115GT-HNTR User's Manual 1.4 Chassis Features Control Panel Power Button NIC LED Information LED UID Botton/LED Node Label Figure 1-1. Control Panel (per node) Control Panel Features Feature Description The main power switch applies or removes primary power from the power supply to the Power Button server but maintains standby power.
  • Page 11: System: Front View

    Chapter 1: Introduction System: Front View The CSE-GT214BC-R2K21BP is a 2U chassis that supports four hot-pluggable nodes. Refer to Appendix B for additional specifications. The chassis front offers access to the storage drives, a control panel for each node, four pullout service tags, and two thumbscrews. Control Panels for Node C (bottom) Control Panels for Node A (bottom) Node Handle...
  • Page 12: System: Rear View

    A+ Server AS -2115GT-HNTR User's Manual System: Rear View The illustration below shows the features on the rear of the chassis. Switch Button Switch Button IPMI (Node D) Switch LED Switch LED IPMI (Node B) PWS1 PWS2 Switch LED Locking Clip IPMI (Node C) Switch LED Locking Lever...
  • Page 13: Motherboard Layout

    Chapter 1: Introduction 1.5 Motherboard Layout Below is a layout of the H13SST-G with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter JFIO1 JAIOM1SB1 JNCSI1 LEDPWR...
  • Page 14: Quick Reference Table

    A+ Server AS -2115GT-HNTR User's Manual Quick Reference Table Jumper Description Default Setting JBT1 CMOS Clear Open (Normal) JSATA1 Hybrid MCIO select Pins 2-3 (SATA) Description Status LED_PWR Power LED Solid Green: Power On LEDBMC BMC Heartbeat LED Green: Blinking (BMC normal), Green: Fast blinking (BMC initializing) Connector Description JNCSI1...
  • Page 15: Block Diagram

    Chapter 1: Introduction Block Diagram H13SST-G FRONT I/O IPMI LAN RJ45 AMD SP5 Rev. 1.02 TS3L500AE COM1 RTL8211F USB 3.0 DDR4 AST2600 BMC ROM USB3.0 [1:0] USB2.0 HUB1 [0] IMPEL PLUS USB2.0 [1] PCIE x16 EMMC HUB 1x4 EMMC CPU G0 [15:0] CPLD BIOS ROM USB2.0 HUB1 [1]...
  • Page 16: Chapter 2 Server Installation

    A+ Server AS -2115GT-HNTR User's Manual Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components.
  • Page 17: Server Precautions

    Chapter 2: Server Installation • Always make sure the rack is stable before extending a server or other component from the rack. • You should extend only one server or component at a time - extending two or more simul- taneously may cause the rack to become unstable.
  • Page 18: Reliable Ground

    A+ Server AS -2115GT-HNTR User's Manual and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Ground A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded.
  • Page 19: Installing The Rails

    Chapter 2: Server Installation 2.3 Installing the Rails This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided.
  • Page 20: Installing The Rails On A Rack

    A+ Server AS -2115GT-HNTR User's Manual Installing the Rails on a Rack 1. Loosen the adjusting screw to allow the rear section to slide in the front section. 2. Push the small hooks on the front section of the rail into the holes on the front post of the rack and then down, until the spring-loaded pegs snap into the rack holes.
  • Page 21: Chassis Installation

    Chapter 2: Server Installation Chassis Installation Slide the chassis into the rack so that the bottom of the chassis slides onto the bottom lip of the rails. Figure 2-3. Sliding the Chassis into the Rack Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing.
  • Page 22: Chapter 3 Maintenance And Component Installation

    A+ Server AS -2115GT-HNTR User's Manual Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 23: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website product pages at https://www.supermicro.com/products/nfo/Ultra.cfm. Node Release Handle...
  • Page 24: Removing Nodes From The Chassis

    A+ Server AS -2115GT-HNTR User's Manual Removing Nodes from the Chassis Each of the four individual nodes may be removed from the chassis without powering down the system. Removing a Node 1. Use the operating system to power down the node and remove any cables attached to the node as described in Section 3.1.
  • Page 25: Removing The Chassis Cover

    Chapter 3: Maintenance and Component Installation Removing the Chassis Cover You can access some chassis components, such as fans, by removing the cover. Removing the Chassis Cover 1. Remove the four screws securing the cover to the chassis. 2. Slide the cover toward the rear of the chassis. 3.
  • Page 26: Static-Sensitive Devices

    A+ Server AS -2115GT-HNTR User's Manual 3.3 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to your motherboard, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD. Precautions •...
  • Page 27: Processor And Heatsink Installation

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the Processor and Heatsink 1. Unscrew the middle screw #1 holding down the force frame.
  • Page 28 A+ Server AS -2115GT-HNTR User's Manual 2. The spring-loaded force frame will raise up after the screw securing it (#1) is removed. Gently allow it to lift up to its stopping position. Force Frame 3. Lift the rail frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the rail frame, lift it to a position so you can do the next step of removing the external cap.
  • Page 29 Chapter 3: Maintenance and Component Installation 4. Remove the external cap from the rail frame by pulling it upwards through the rail guides on the rail frame. External Cap 5. The CPU package is shipped from the factory with the carrier frame pre-assembled. Grip the handle of the carrier frame/CPU package assembly from its shipping tray, and while gripping the handle, align the flanges of the carrier frame onto the rails of the rail frame so its pins will be at the bottom when the rail frame is lowered later.
  • Page 30 A+ Server AS -2115GT-HNTR User's Manual Note: You can only install the CPU inside the socket in one direction with the handle at the top. Make sure that it is properly inserted into the CPU socket before closing the rail frame plate.
  • Page 31 Chapter 3: Maintenance and Component Installation 8. Gently lower the rail frame down onto the socket until the latches on the rail frame engage with the socket housing and it rests in place. DO NOT force it into place! 9. The force frame is spring loaded and has to be held in place before it is secured. Important: Use a torque screwdriver, set it at 12.5~15.0 kgf-cm (10.85~13.01 lbf-in) with a Torx T20 screw head bit, to prevent damage to the CPU.
  • Page 32 A+ Server AS -2115GT-HNTR User's Manual 10. Replace and tighten the screws in the same order you removed them. When finished, the force frame will be secure over both the rail frame and CPU package. 11. After the force frame is secured and the CPU package is in place, now you must install the heatsink to the frame.
  • Page 33 Chapter 3: Maintenance and Component Installation 12. Using a diagonal pattern, tighten the six screws down on the heatsink in a clockwise fashion till it is secure. The heatsink will now be secured and you have finished installing the processor and heatsink onto the motherboard. Repeat this procedure for any remaining CPU sockets on the motherboard.
  • Page 34 A+ Server AS -2115GT-HNTR User's Manual Removing the Processor and Heatsink 1. Remove the heatsink attached to the top of the CPU package by reversing the installation procedure. 2. Clean the thermal grease left by the heatsink on the CPU package lid to limit the risk of it contaminating the CPU package land pads or contacts in the socket housing.
  • Page 35: Memory

    The H13SST-G supports up to 3TB of ECC DDR5 4800 MT/s speed, RDIMM/LRDIMM/3DS memory in 12 slots. Refer to the table below for additional memory information. Notes: Check the Supermicro website for possible updates to memory support. DIMM Population Guide...
  • Page 36: Dimm Module Population Sequence

    A+ Server AS -2115GT-HNTR User's Manual DIMM Module Population Sequence • It is recommended that DDR5 DIMM modules of the same type, size and speed should be installed. • The motherboard will support odd-numbered modules (1 or 3 modules installed). However, to achieve the best memory performance, fully populate the motherboard with validated memory modules.
  • Page 37: Dimm Installation

    Chapter 3: Maintenance and Component Installation DIMM Installation 1. Insert the desired number of DIMMs into the memory slots, there is no specific sequence or order required. 2. Push the release tabs outwards on both ends of the DIMM slot to unlock it. Receptive Point 3.
  • Page 38: Motherboard Battery

    A+ Server AS -2115GT-HNTR User's Manual Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in Section 3.1.
  • Page 39: Chassis Components

    Status LED Do not remove NVMe device Amber Blinking at 1 Hz Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website product pages at www.supermicro.com/products.
  • Page 40: Drive Configuration

    A+ Server AS -2115GT-HNTR User's Manual Drive Configuration The CSE-GT214BC-R2K21BP chassis contains four separate computing node drawers, each with its own motherboard. Each node controls a set of six drives. If a node drawer is pulled out of the chassis, the drives associated with that node will power down. Storage cables are not included by default.
  • Page 41: Removing/Installing Drives

    Chapter 3: Maintenance and Component Installation Removing/Installing Drives Removing a Drive Carrier from the Chassis 1. Push the release button on the drive carrier. This releases and extends the drive carrier handle. If the release button does not release it, the handle may be locked. Use a flathead screwdriver and rotate the screw counterclockwise 45 degrees to unlock the handle.
  • Page 42 A+ Server AS -2115GT-HNTR User's Manual Installing a 2.5" Hard Drive into the Hard Drive Tray 1. Place the hard drive carrier on a flat surface. 2. Orient the drive with the connector facing the bottom rear of the carrier. The drive can be inserted from above into the clips until a "click"...
  • Page 43: Hot-Swap For Nvme Drives

    Chapter 3: Maintenance and Component Installation Hot-Swap for NVME Drives Supermicro servers support NVMe surprise hot-swap. For even better data security, NVMe orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely using BMC. Ejecting a Drive 1. BMC > System > Storage Monitoring > Physical View 2.
  • Page 44: Checking The Temperature Of An Nvme Drive

    BMC > Sensor Reading – Shows the single highest temperature among all the NVMe drives. AIOM Card The Supermicro Advanced Input/Output Module (AIOM) card provides options for network connection. It is inserted into an AIOM slot on the motherboard tray. Removing the AIOM Card 1.
  • Page 45: I/O Card Module

    Chapter 3: Maintenance and Component Installation I/O Card Module The I/O card module provides options for input/output connections for different devices. It is inserted into the I/O slot in the chassis. Removing the I/O Card Module 1. Power down the system as described in Section 3.1 and remove the cover.
  • Page 46: System Cooling

    A+ Server AS -2115GT-HNTR User's Manual 3.7 System Cooling Fans Fan speed is controlled by a system temperature setting in IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model.
  • Page 47: Installing The Air Shroud

    Chapter 3: Maintenance and Component Installation Installing the Air Shroud Air shrouds help to funnel the airflow provided by the fans over the system components that generate the most heat. The system requires air shrouds for each node to maximize airflow efficiency.
  • Page 48: Power Supply

    The chassis features dual redundant power supplies. The power modules can be changed without powering down the system. Please exchange the power modules within one minute. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are auto-switching capable. This feature enables them to automatically sense the input voltage and operate at a 100-120v or 180-240v.
  • Page 49: Bmc Reset

    Chapter 3: Maintenance and Component Installation 3.9 BMC Reset The BMC can be reset using the button on the front control panel or on the chassis rear. • Reset – Press and hold the button. After six seconds, the LED blinks at 2Hz. The BMC resets and the reset duration is ~250 ms.
  • Page 50: Chapter 4 Motherboard Connections

    A+ Server AS -2115GT-HNTR User's Manual Chapter 4 Motherboard Connections This section describes the connections, jumpers and LED indicators on the motherboard and provides pinout definitions. Not all connections are required. A motherboard layout indicating component locations may be found in Chapter Please review the Safety Precautions in Appendix A...
  • Page 51: Headers And Connectors

    Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions. Please go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module Header Pin Definitions...
  • Page 52: Jumper Settings

    A+ Server AS -2115GT-HNTR User's Manual 4.3 Jumper Settings How Jumpers Work To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin #1 is identified with a square solder pad on the printed circuit board.
  • Page 53 Chapter 4: Motherboard Connections JSATA1 The 3-pin jumper at JSATA1 provides the option to switch the hybrid port (JMCIO5) between SATA/NVMe. Refer to the table below for pin definitions. JSATA1 Pin Definitions Pin# Definition Auto (Depends on system configuration) SATA Open NVMe...
  • Page 54: Led Indicators

    A+ Server AS -2115GT-HNTR User's Manual 4.4 LED Indicators Onboard Power LED LED_PWR is an onboard power LED. When this LED is lit, it means the system is in a power- on state, and the onboard power status is ok. Turn off the system and unplug the power cord before removing or installing components.
  • Page 55: Chapter 5 Software

    1. Create a method to access the Microsoft Windows installation ISO file. That can be a USB flash or media drive. 2. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 56 A+ Server AS -2115GT-HNTR User's Manual 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner.
  • Page 57: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash or media drive.
  • Page 58: Superdoctor®5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 59: Ipmi

    BIOS settings that are related to IPMI. For general documentation and information on IPMI, visit our website at: http://www.supermicro.com/products/nfo/IPMI.cfm. BMC ADMIN User Password For security, each system is assigned a unique default BMC password for the ADMIN user.
  • Page 60: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 61 Appendix A: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 62 A+ Server AS -2115GT-HNTR User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 63 Appendix A: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 64 A+ Server AS -2115GT-HNTR User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 65 Appendix A: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 66 A+ Server AS -2115GT-HNTR User's Manual ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 67 Appendix A: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 68 A+ Server AS -2115GT-HNTR User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 69 Appendix A: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 70 A+ Server AS -2115GT-HNTR User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가...
  • Page 71 Appendix A: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 72 A+ Server AS -2115GT-HNTR User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意ください。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 73 Appendix A: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 74 A+ Server AS -2115GT-HNTR User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 75 Appendix A: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 76 A+ Server AS -2115GT-HNTR User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 77 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 78 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 79 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 80: Appendix B System Specifications

    A+ Server AS -2115GT-HNTR User's Manual Appendix B System Specifications Processor Support AMD EPYC 9004 series processors in Socket SP5 Chipset System on Chip (SoC) BIOS AMI 32MB SPI Flash EEPROM Memory (per node) Up to 3TB registered ECC DDR5 4800 MT/s speed in 12 DIMM slots Drive Bays (per node) Six 2.5"...
  • Page 81 Appendix B: System Specifications Regulatory Compliance FCC, ICES, CE, VCCI, RCM, NRTL, CB, UKCA, KCC, BSMI Applied Directives, Standards Electromagnetic Compatibility Regulations 2016 FCC Part 15 ICES-003 VCCI-CISPR 32 AS/NZS CISPR 32 BS/EN 55032 BS/EN 55035 CISPR 32 CISPR 35 BS/EN 61000-3-2 BS/EN 61000-3-3 BS/EN 61000-4-2...
  • Page 82: Bsmi Compliance

    A+ Server AS -2115GT-HNTR User's Manual BSMI Compliance 限 限 用 用 物 物 質 質 含 含 有 有 情 情 況 況 標 標 示 示 聲 聲 明 明 書 書 Declaration of the Presence Condition of the Restricted Substances Marking 伺服器...
  • Page 83 Appendix B: System Specifications 警告: 為避免電磁干擾, 本產品不應安裝或使用於住宅環境。 輸入額定 100-127V ~, 60-50Hz, 12-11A (x2) 200-240V ~, 60-50Hz, 10-9.8A (x2) *使用者不能任意拆除或替換內部配備 *報驗義務人之姓名或名稱:美超微電腦股份有限公司 *報驗義務人之地址:新北市中和區建一路 150 號 3 樓...

Table of Contents