SGM LEKTRA PTU05 Quick Start Manual

Compact ultrasonic level transmitter

Advertisement

Quick Links

Technical Data
Enclosure material:
Mechanical installation:
on request with PP DN100 flange screwed
Mechanical protection:
Electrical connection:
Working temperature:
Pressure:
Power supply:
Power consumption:
Serial port:
Max measure range:
[The above distance must be intended from perfect
reflecting surfaces]
Blocking distance:
Temperature compensation:
Accuracy:
Resolution:
Calibration:
Warm-up:
LEDs display:
yellow LED flashing for echo receiving
A)
B)
D)
E)
fig.2
Compact ultrasonic level transmitter
1" BSP
n.1 output cables (L=3m)
-25 a +75°C
from 0,5 to 1,5bar (absolute)
PT100 from -30 to +80°C
+/- 1%
not better than +/-2mm
by SWING unit
30 minutes normally
red LED for supply
C)
applied solutions for the application
PTU05
PP
IP68
24Vdc
1W
RS485
5m
0.3m
1mm
PTU05
Important close to the sensor there is a "blind zone" of 0,3m
where the equipment can't measure.
To reach a good and safe measurement, avoiding spurious
echo (not reflected from the surface to measure) need to take
care about the sensor sensibility volume in the sound path, no
obstacles or objects must be present into the sensibility volume
(lobe), see fig.2/D/E.
On fig.2 some suggestion:
1) Install perpendiculary at the surface, see fig.2/A
2) Don't use with foaming products, see fig.2/B
3) Avoid installation where the product distance could be less
than 0,3m, see fig.2/C
4) No obstacles or objects must be present into the
sensibility volume, see fig.2/D/E
Mechanica installation
PTU05 mA GB
fig.1
.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PTU05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SGM LEKTRA PTU05

  • Page 1 PTU05 mA GB PTU05 Compact ultrasonic level transmitter Technical Data Enclosure material: Mechanical installation: 1” BSP on request with PP DN100 flange screwed Mechanical protection: IP68 Electrical connection: n.1 output cables (L=3m) Working temperature: -25 a +75°C Pressure: from 0,5 to 1,5bar (absolute)
  • Page 2 In the condition of normal working the PTU05 shows led flashing (when echo is received). To calibrate 4mA needs to put the PTU05 at the distance at which you want 4mA output current. Wait till the led is flashing than: press simultaneously P1 and P2, release them and verify that led will stay fix lightened.
  • Page 3 PTU05 Electrical Connections fig.C fig.B...
  • Page 4 In conformity to the company and ceck procedure I certify configuration is made from that the equipment: SWING unit. PTU05 ..... Serial n....... is conform to the technical requirements on Technical Data and it is made in conformity to the SGM-LEKTRA procedure Quality Control Manager .....................