Technical Data
Housing material:
Mechanical installation:
Protection degree:
Electrical connection:
Working temperature:
Pressure:
Power supply:
Power consumption:
Analog output:
Digital communication:
Max measure range: PTU50 0.05÷1.5m; PTU51 0.3÷6m;
[In case of non perfectly reflecting surfaces, the maximu
Temperature compensation: digital in the working temperature
±0,2% (of the measured distance)
Accuracy:
not better than ±3mm (PTU50 ±1mm)
Resolution:
VLW601 prog. module with 4 buttons
Calibration:
Warm-up:
LCD Display: matrix LCD display on VLW601 module (opt.)
Warranty
Products supplied by SGM LEKTRA are guaranteed for a period of 12 (twelve) months from delivery date according to
the conditions specified in our sale conditions document.
SGM LEKTRA can choose to repair or replace the Product.
If the Product is repaired it will mantein the original term of guarantee, whereas if the Product is replaced it will have 12
(twelve) months of guarantee.
The warranty will be null if the Client modifies, repair or uses the Products for other purposes than the normal conditions
foreseen by instructions or Contract.
In no circumstances shall SGM LEKTRA be liable for direct, indirect or consequiential or other loss or damage whether
caused by negligence on the part of the company or its employees or otherwise howsoever arising out of defective goods
Factory Test Certificate
In conformity to the company and check procedures I certify that the equipment:
PTU
...................
Serial n. .......................................................
is conform to the technical requirements on Technical Data and it is made in conformity to the SGM-LEKTRA procedure
Quality Control Manager
PTU50-51-56
Ultrasonic level transmitter
1"GAS M; (PP flange DN100 opt.)
IP68 male connector
with 5/10/15/20m linking cable
-25° ÷ +75°C
da 0,5 a 1,5 bar (absolute)
4÷20mA max 750ohm
MODBUS RTU
PTU56 0,5÷12m
distance value will be reduced]
or by MODBUS RTU
30 minutes typical
Production and check date:
.................................
Process Controll and Measurement
PP
IP68
24Vdc
1,5W
1mm
PTU50
................................
825B124C
PTU51
PTU56

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PTU5 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SGM LEKTRA PTU5 Series

  • Page 1 LCD Display: matrix LCD display on VLW601 module (opt.) Warranty Products supplied by SGM LEKTRA are guaranteed for a period of 12 (twelve) months from delivery date according to the conditions specified in our sale conditions document. SGM LEKTRA can choose to repair or replace the Product.
  • Page 2: Installation Precaution

    PTU5x - Safety / Mechanical installation The non intrusive system application is now preferred in the level measurements field. For this reason the SGM-LEKTRA developed the PTU50, PTU51 and PTU56 unity to best meet the “GENERAL-PURPOSE” application requests. The PTU50, PTU51 and PTU56 units are compact sensors and have a via connector quick connection. The IP68 protection makes them suitable for external applications with direct exposure to the weather, including areas with diving hazard (up to 1m).
  • Page 3: Mechanical Installation

    PTU5x - Mechanical installation 2.2 Mounting examples Fig.7 Fig.5 Fig.5.b Fig.6 2.3 Mounting precautions 2.3.1 Mounting position (Fig.8) Fig.8 - With cambered roof, Do not install the sensor in the tank center (b). Leave a 300mm minimum distance between the sensor and the tank smooth wall (d).
  • Page 4 PTU5x - Mechanical installation 2.3.4 Reference pipe installation Disturbing factors that may influence the level measurement in liquids, as for example: - foam presence on the product surface (Fig.12) - internal structures presence in the tank (Fig.13) - presence on the liquid surface of floating bodies (Fig.14) can be avoided with the use of level measurement inside of pipes (by-pass pipe or calm pipe with 100mm min.
  • Page 5: Configuration Modes

    PTU5x - Connections and Configuration 3. CONNECTIONS 3.1 Wiring 1) Separate the engine control cables or power cables from the PTU5x connection cables. 2) Isolate unused wires of the cable. 3) Fully tighten the connector ring nut Brown GND (0V) Green A (RS485) Blue...
  • Page 6: Quick Start Mode

    PTU5x - Configuration and Quick Start The VLW601 program module has 4 buttons (fig. 21) which allow to perform all operational, control and programming instrument functions. In the configuration menus, is possible: a) Submenus and parameters access; press to select and press to access.
  • Page 7 PTU5x - Quick Start 5.1 Struttura menù di configurazione rapida Parameters Default Values 1500mm (PTU50 1.5m max) Set Distance 4mA 6000mm (PTU51 6m max) 0000 mm 12000mm (PTU56 8m max) 100mm (PTU50 1.5m max) Set Distance 20mA 400mm (PTU51 6m max) Quick Setup 0000 mm Set Distance 4mA 600mm (PTU56 8m max) Prodotto...
  • Page 8 PTU5x - Quick Start 5.1.4 FILTER COEFFICIENT Fast resp. Normal resp. Slow resp. 5÷10 40÷100 Press . Increasing the value slows down the sensor response speed. to modify the value. Input a value from 1 to to confirm. 99. Press In fig.24 value choice Fig.24 example.

This manual is also suitable for:

Ptu50Ptu51Ptu56

Table of Contents