Technical Data
Housing material:
Mechanical installation:
Protection degree:
Electrical connection:
Working temperature:
Pressure:
Power supply:
Power consumption:
Analog output:
Digital communication:
Max measure range: PTU50 0.05÷1.5m; PTU51 0.3÷6m;
[In case of non perfectly reflecting surfaces, the maximu
Temperature compensation: digital in the working temperature
±0,2% (of the measured distance)
Accuracy:
not better than ±3mm (PTU50 ±1mm)
Resolution:
VLW601 prog. module with 4 buttons
Calibration:
Warm-up:
LCD Display: matrix LCD display on VLW601 module (opt.)
Warranty
Products supplied by SGM LEKTRA are guaranteed for a period of 12 (twelve) months from delivery date according to
the conditions specified in our sale conditions document.
SGM LEKTRA can choose to repair or replace the Product.
If the Product is repaired it will mantein the original term of guarantee, whereas if the Product is replaced it will have 12
(twelve) months of guarantee.
The warranty will be null if the Client modifies, repair or uses the Products for other purposes than the normal conditions
foreseen by instructions or Contract.
In no circumstances shall SGM LEKTRA be liable for direct, indirect or consequiential or other loss or damage whether
caused by negligence on the part of the company or its employees or otherwise howsoever arising out of defective goods
Factory Test Certificate
In conformity to the company and check procedures I certify that the equipment:
PTU
...................
Serial n. .......................................................
is conform to the technical requirements on Technical Data and it is made in conformity to the SGM-LEKTRA procedure
Quality Control Manager
PTU50-51-56
Ultrasonic level transmitter
1"GAS M; (PP flange DN100 opt.)
IP68 male connector
with 5/10/15/20m linking cable
-25° ÷ +75°C
da 0,5 a 1,5 bar (absolute)
4÷20mA max 750ohm
MODBUS RTU
PTU56 0,5÷12m
distance value will be reduced]
or by MODBUS RTU
30 minutes typical
Production and check date:
.................................
Process Controll and Measurement
PP
IP68
24Vdc
1,5W
1mm
PTU50
................................
825B124C
PTU51
PTU56
Need help?
Do you have a question about the PTU5 Series and is the answer not in the manual?