Technical Information
4.10
Self Clean Temperature Sensor (3R30 & 6R30)
(Self Clean Models Only)
The Self Clean Temperature Sensor is located in the Vapor Outlet
(above the Catalyst) and monitors the oven temperature during the Self
Clean Mode. Refer to Figure 4-4.
1. Self Clean Temperature Sensor
2. Catalyst Vapor Outlet
Figure 4-4: Self Clean Temperature Sensor and Catalyst Vapor Outlet
4.11
Thermal Cut-Outs (1F1 & 3F1)
Each separate oven cavity is equipped with a High Temperature Thermal
Cut-Out. The cut out is designed to interrupt the power in should the
temperature exceed 680
4.12
Thermal Cut-Outs (2F1 & 4F1)
(Self Clean Models Only)
Each separate oven cavity is equipped with a High Temperature Thermal
Cut-Out designed to interrupt the power should the temperature exceeds
o
968
F (520
o
o
F (360
o
C) during the Self Clean mode.
30
C) during operation modes.
Master Chef Ovens