Download Print this page
M-system 47NL Series Manual

M-system 47NL Series Manual

Digital panel meters

Advertisement

Quick Links

Digital Panel Meters 47NL Series
LOOP POWERED DIGITAL PANEL METER
(4 1/2 digit, LED display type)
Functions & Features
• 4 ½ digit loop powered digital panel meter
• No external power source needed
• Moving average function to suppress the display flickering
• Scaling, forced zero, low-end cutout
• Max. and Min. value display
96.0 (3.78)
48.0
(1.89)
Ma x/M in
Sc ale /
Sh ift
Up
MODEL: 47NLN-[1][2]
ORDERING INFORMATION
• Code number: 47NLN-[1][2]
Specify a code from below for each of [1] and [2].
(e.g. 47NLN-R/Q)
• Specify the specification for option code /Q
(e.g. /SET)
INPUT
Current
4 – 20 mA DC
[1] DISPLAY COLOR
R: Red
G: Green
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9563)
https://www.m-system.co.jp/
20.0 (.79)
mm (inch)
47NLN SPECIFICATIONS
GENERAL SPECIFICATIONS
Construction: Panel mount type
Degree of protection: IP66; Applicable to the front of the
panel meter mounted according to the specified panel
cutout. Only screw mounting conforms.
Connection: Screwless spring terminal
Applicable wire size: 0.2 to 0.5 mm
Housing material: Flame-resistant resin (gray)
Setting: (Front button)
• Scaled range
• Moving average
• Others
(Refer to the instruction manual for details)
Averaging: None or moving average
Lockout setting: Prohibiting certain operations; protecting
settings
DISPLAY
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED
Display range: -19999 to 19999
Decimal point position: 10
Zero indication: Higher-digit zeros are suppressed.
Over-range indication: '-19999' or '19999' blinking for
display values out of the display range.
'S.ERR' and 'Min' or 'Max' blinking when the input signal is
out of the usable range.
Function indicators:
Zro, Spn, D/P, Tch, Fnc, Min, Max
Display mode status and operation status, ON or blink
(Display color is the same as display color code.)
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
2
m/h, m/s
, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m
3
3
3
m
/min, m
/h, Nm
/h, N·m, N/m
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, pH, %, ppm, etc.
INPUT SPECIFICATIONS
■ DC Current
Current range: Approx. 3.7 to 23 mA DC
Voltage drop: Approx. 6.3 V with 4 mA; approx. 6.5 V with
20 mA (Equivalent input impedance: Approx. 325 Ω)
(There is voltage drop generated by using the unit. For the
two-wire transmitter power supply, make sure that the
operable voltage for the two-wire transmitter is ensured
including the voltage drop by other devices and wiring
resistance.)
MODEL: 47NLN
2
, stripped length 6 mm
–1
–2
–3
–4
, 10
, 10
, 10
or none
3
3
, m
/sec,
2
, g, kg, kg/h,
ES-9563 Rev.4 Page 1/4

Advertisement

loading

Summary of Contents for M-system 47NL Series

  • Page 1 MODEL: 47NLN Digital Panel Meters 47NL Series GENERAL SPECIFICATIONS Construction: Panel mount type Degree of protection: IP66; Applicable to the front of the LOOP POWERED DIGITAL PANEL METER panel meter mounted according to the specified panel (4 1/2 digit, LED display type) cutout.
  • Page 2 Used to move on to the setting standby status of each setting mode or to shift through display digits in each setting item. (7) Up button Used to change setting values, to execute/cancel Forced Zero or to select setting values. Note: Refer to the operating manual for details on each function. 47NLN SPECIFICATIONS ES-9563 Rev.4 Page 2/4 https://www.m-system.co.jp/...
  • Page 3   (Conform to degree of protection IP66)   (Not conform to degree of protection IP66) Panel cutout must be such as M-System specified. Use Panel cutout is not required. Use magnet sheet and stopper watertight packing and unit fixing screws included in the included in the product package.
  • Page 4 Digital Two-wire Transmitter Computation Display / Setting Power Source ■ 4-WIRE CONNECTION EXAMPLE INPUT – Controllor, etc. I/P Positioner, etc. 4 – 20mA DC – – Specifications are subject to change without notice. 47NLN SPECIFICATIONS ES-9563 Rev.4 Page 4/4 https://www.m-system.co.jp/...

This manual is also suitable for:

47nln