Installation of Outdoor Unit

1. Remove the handle on the right side plate of outdoor unit.
2.Take off wire clamp. Connect and fix the power connection
cord to the terminal board. Wiring should fit that of
indoor unit.
3.Fix the power connection cord with wire clamp.
4.
Confirm if the wire has been fixed properly.
5.
Reinstall the handle
NOTE:
Incorrect wiring may cause malfunction of spare part.
After the wire has been fixed, ensure there is free
space between the connection and fixing places
on the lead wire.
1. Connect charging hose of manifold valve to charge end of low pressure
valve (both high/low pressure valves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open the handle of Lo manifold valve.
4. Open the vacuum pump for vacuumization. At the beginning,
slightly loosen joint nut of low pressure valve to check
if there is air coming inside. (If noise of vacuum pump
has been changed, the reading of multimeter is 0) Then
tighten the nut.
5. Keep vacuuming for more than 15mins and make
sure the reading of multi-meter is
(-76cmHg) . .
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low pressure valve.
8. Tighten lid of low pressure valve. (As shown in Fig.10)
Outdoor
During heating operation, the
water should be drained out reliably through the drain hose.
Install the outdoor drain connector in a Φ25 hole
the
base plate and attachthe drain hose to the
so
that the waste water formed in the outdoor unit can be
drained ou t
.The hole diameter 25 must be plugged.
Whether to plug other holes will be determined by the dealers according to actual conditions.
Electric Wiring
Air Purging and Leakage Test
-1.0
10 pa
Condensate
Drainage (only for Heat pump unit)
condensate
and defrosting
26
Handle
Low-pressure
valve (Lo) Open
Liquid valve
5
on
connector
N(1)
2
3
L
N
yellow-
green
blue black brown
brown blue
N
L
Indoor unit connection
Power
Manometer
-76cmHg
High-pressure
valve (Hi) closed
Charging hose
Vacuum
Gas valve
pump
Fig.10
Drain-water hole
Bottom frame
Drain plug
Drain connecter
Hose (available commercially,
inner dia. 16mm)
yellow-
green