Notices for Installation
1. The air inlet and outlet should be away from the obstructions. Ensure the air can be
blown through the whole room.
2. Select a site where the condensing water can be easily drained out, and where it is
easily connected for outdoor unit.
3. Select a place where it is out of reach of children.
4. Select the place where the wall is strong enough to withstand the full weight and vibration
of the unit.
5. Be sure to leave enough space to allow access for routine maintenance. The installation
site should be 250cm or more above the floor.
6. Select a place about 1m or more away from TV set or any other electric appliance.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit is installed in accordance with installation dimension
instructions.
9. Do not use the unit in the laundry or by swimming pool etc.
1. Select a site where noise and outflow air emitted by unit will not annoy neighbors.
2.
Select a site where there is sufficient ventilation.
3.
Select a site where there is no obstruction blocking the inlet and outlet.
4.
The site should be able to withstand the full weight and vibration.
5.
Select a dry place, but do not expose the unit to direct sunlight or strong wind.
6.
Make sure that the outdoor unit is installed in accordance with the installation instructions,
and is convenient for maintenance and repair.
7.
The height difference between indoor and outdoor units is within 5 m, and the length of
the connecting tubing does not exceed 10 m.
8.
Select a place where it is out of reach of children.
9.
Select a place which will not block pedestrian passage and influence the city appearance.
1. A dedicated power supply circuit should be used in accordance with local electrical
safety regulations.
2. Don't drag the power cord emphatically.
3. The unit should be reliably earthed and connected to the special earth device by the
professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent
short circuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6.
The appliance shall be installed in accordance with national wiring regulations.
7.
An all-pole disconnection switch with a contact separation of at least 3mm in all poles
should be connected in fixed wiring.For models with a power plug, make sure the plug is
within reach after installation.
8. Including an air switch with suitable capacity, please note the following table. Air switch
should be included magnet buckle and heating buckle function, it can protect the circuit-
short and overload. (Caution: please do not use the fuse only for protect the circuit)
Installation Site of Indoor Unit
Installation Site of Outdoor Unit
Safety Precautions for Electric Appliances
20