Use In Difficult Operating Conditions; Technical Data; Rtp0-Kb - YASKAWA 67S-RTP0-KB Manual

Table of Contents

Advertisement

Hardware description
Technical data > 67S-RTP0-KB
EMC
Emitted interference
Noise immunity
zone B
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is
necessary.

2.6 Use in difficult operating conditions

2.7 Technical data

2.7.1 67S-RTP0-KB
Order no.
Type
Display
Display size (diagonal)
Display size (width)
Display size (height)
Resolution
Aspect ratio
Type of display
MTBF Backlights (25°C)
System properties
18
Standard
EN 61000-6-4
EN 61000-6-2
EN 61000-4-2
EN 61000-4-3
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
Without additional protective measures, the products must not be used in
locations with difficult operating conditions; e.g. due to:
dust generation
chemically active substances (corrosive vapors or gases)
strong electric or magnetic fields
Comment
Class A (Industrial area)
Industrial area
ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2)
HF field immunity (casing)
80MHz ... 1000MHz, 10V/m, 80% AM (1kHz)
1.4GHz ... 6.0GHz, 3V/m, 80% AM (1kHz)
HF conducted
150kHz ... 80MHz, 10V, 80% AM (1kHz)
Burst, degree of severity 3
Surge, degree of severity 3
67S-RTP0-KB
Panel PC PPC021 IE
21.5 "
478 mm
269 mm
1080 x 1920 / 1920 x 1080
16:9
TFT color (16.7M colors)
50000 h
HB160 | PPC | 67S-RTP0-KB | en | 23-20
1
HMI

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ppc021 ie