Advertisement

Quick Links

VIPA HMI
PPC | 67P-PNL0 | Manual
HB160 | PPC | 67P-PNL0 | en | 20-20
Panel PC - PPC015 ES

Advertisement

Table of Contents
loading

Summary of Contents for YASKAWA 67P-PNL0-JB

  • Page 1 VIPA HMI PPC | 67P-PNL0 | Manual HB160 | PPC | 67P-PNL0 | en | 20-20 Panel PC - PPC015 ES...
  • Page 2 YASKAWA Europe GmbH Ohmstraße 4 91074 Herzogenaurach Tel.: +49 9132 744 0 Fax: +49 9132 744 186 Email: info@yaskawa.eu.com Internet: www.yaskawa.eu.com 67P-PNL0_000_PPC015ES,9,EN - © 2020...
  • Page 3: Table Of Contents

    VIPA HMI Table of contents Table of contents General........................4 1.1 Copyright © YASKAWA Europe GmbH............4 1.2 About this manual..................... 5 1.3 Safety information..................... 6 Hardware description..................... 7 2.1 Safety information for users................7 2.2 Properties......................8 2.3 Structure......................9 2.3.1 Overview......................
  • Page 4: General

    This material is protected by copyright laws. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to YASKAWA) except in accordance with applicable agreements, contracts or licensing, without the express written consent of YASKAWA and the business management owner of the material.
  • Page 5: About This Manual

    About this manual Document support Contact your local representative of YASKAWA Europe GmbH if you have errors or ques- tions regarding the content of this document. If such a location is not available, you can reach YASKAWA Europe GmbH via the following contact: YASKAWA Europe GmbH, Ohmstraße 4, 91074 Herzogenaurach, Germany...
  • Page 6: Safety Information

    VIPA HMI General Safety information CAUTION! Damages to property is likely if these warnings are not heeded. Supplementary information and useful tips. 1.3 Safety information Applications conforming The system is constructed and produced for: with specifications communication and process control general control and automation tasks industrial applications operation within the environmental conditions specified in the technical data...
  • Page 7: Hardware Description

    VIPA HMI Hardware description Safety information for users Hardware description 2.1 Safety information for users Handling of electrostatic VIPA-modules make use of highly integrated components in MOS-Technology. These sensitive modules components are extremely sensitive to over-voltages that can occur during electrostatic discharges.
  • Page 8: Properties

    Embedded Standard 7 - WES7. Besides the extensive WES7 functions the Panel PC offers varied communication possibilities. Ò Windows Embedded Standard 7 Movicon 11 Win Standard 7 (67P-PNL0-JB) 15.6" 16:9 TFT panel 16.7 M color PCAP, multitouch Display resolution 1366 x 768 Ò...
  • Page 9: Structure

    VIPA HMI Hardware description Structure > Overview 2.3 Structure 2.3.1 Overview Front view Slot for voltage supply (DC 12-30V) VGA interface Reset button RS232/RS422/RS485 interface COM 2 RS232/RS422/RS485 interface COM 1 4x"Host"-USB-A interface RJ45 jack for Ethernet communication LAN 2 RJ45 jack for Ethernet communication LAN 1 3.5mm Audio Line out 10 Power switch (pushbutton)
  • Page 10 VIPA HMI Hardware description Structure > Overview Bottom view Slot for voltage supply (DC 12-30V) VGA interface Reset button RS232/RS422/RS485 interface COM 2 RS232/RS422/RS485 interface COM 1 4x"Host"-USB-A interface RJ45 jack for Ethernet communication LAN 2 RJ45 jack for Ethernet communication LAN 1 3.5mm Audio Line out Please make sure that the Panel PC always has to be supplied with external voltage!
  • Page 11: Interfaces

    VIPA HMI Hardware description Structure > Interfaces 2.3.2 Interfaces HB160 | PPC | 67P-PNL0 | en | 20-20...
  • Page 12 VIPA HMI Hardware description Structure > Interfaces RS232/RS422/RS485 inter- The 9-pin male SubD connector may be switched with BIOS. Here also the termination face (switchable) resistor of the RS422 and RS485 interface may be activated or deactivated. Ä ‘Submenu "Serial Port 1 Configuration"’ page 42 RS232 interface Logical conditions as voltage level Point-to-point connection with serial full-duplex transfer...
  • Page 13 VIPA HMI Hardware description Structure > Interfaces HB160 | PPC | 67P-PNL0 | en | 20-20...
  • Page 14: Memory Management

    VIPA HMI Hardware description Structure > Memory management VGA interface VGA SubD HD15 jack to connect a second display. Line out 3.5 mm stereo jack to connect an active speaker system or an earphone. "Host"-USB-A Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be connected.
  • Page 15: Dimensions

    VIPA HMI Hardware description Dimensions Assignment Assignment n.c. SATA_TX1+ SATA_TX1- CFAST_LED1_C CFAST_LED2_C SATA_RX1+ PC10 n.c. SATA_RX1- PC11 n.c. PC12 n.c. CFAST_CDI PC13 VCC3 PC14 VCC3 n.c. PC15 n.c. PC16 n.c. PC17 CFAST_CDO Prior to removing the CFast card, make sure the unit's power is off and disconnected from the power supply.
  • Page 16 VIPA HMI Hardware description Dimensions 15.6" - 67P-PNL0-... Front panel thickness 3 ... 12mm Installation cutting (W x H) 401 x 296mm Front panel (W x H x T) 417.80 x 312.80 x 6.20mm Rear panel (W x H x D) 396 x 291 x 57.60mm Installation depth 57.60mm...
  • Page 17: General Data

    VIPA HMI Hardware description General data 2.5 General data Conformity and approval Conformity 2014/35/EU Low-voltage directive 2014/30/EU EMC directive Approval Refer to Technical Data others RoHS 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment Protection of persons and device protection Type of protection IP20...
  • Page 18: Technical Data

    VIPA HMI Hardware description Technical data > 67P-PNL0-JB Standard Comment Emitted interference EN 61000-6-4 Class A (Industrial area) Noise immunity EN 61000-6-2 Industrial area zone B EN 61000-4-2 8kV at air discharge (degree of severity 3), 4kV at contact discharge (degree of severity 2)
  • Page 19 VIPA HMI Hardware description Technical data > 67P-PNL0-JB Order no. 67P-PNL0-JB CF Card Slot Typ II CFast Slot ü Time Real-time clock buffered ü Clock buffered period (min.) Type of buffering lithium battery Load time for 50% buffering period Load time for 100% buffering period Accuracy (max.
  • Page 20 VIPA HMI Hardware description Technical data > 67P-PNL0-JB Order no. 67P-PNL0-JB Current consumption (rated value) 1.3 A Inrush current 1.3 A I²t 0.35 A²s Power loss 32 W Status information, alarms, diagnostics Supply voltage display none Mechanical data Housing / Protection class...
  • Page 21: Pnl0-Jx

    VIPA HMI Hardware description Technical data > 67P-PNL0-JX 2.6.2 67P-PNL0-JX Order no. 67P-PNL0-JX Type VIPA Panel PC PPC015 ES Display Display size (diagonal) 15.6 " Display size (width) 344 mm Display size (height) 195 mm Resolution 768 x 1366 / 1366 x 768 Aspect ratio 16:9 Type of display...
  • Page 22 VIPA HMI Hardware description Technical data > 67P-PNL0-JX Order no. 67P-PNL0-JX COM1 connector Sub-D, 9-pin, male Serial, COM2 RS232 / RS422 / RS485 COM2 connector Sub-D, 9-pin, male Number of USB-A interfaces USB-A connector USB-A (host) Number of USB-B interfaces USB-B connector Number of ethernet interfaces Ethernet...
  • Page 23 VIPA HMI Hardware description Technical data > 67P-PNL0-JX Order no. 67P-PNL0-JX Width 401 mm Height 296 mm Minimum 3 mm Maximum front panel thickness 12 mm Net weight 6.2 kg Weight including accessories Gross weight Environmental conditions Operating temperature 0 °C to 50 °C Storage temperature -20 °C to 75 °C Certifications...
  • Page 24: Deployment Panel Pc

    VIPA HMI Deployment Panel PC Installation Deployment Panel PC 3.1 Installation Overview The Panel PC is suitable for the installation in operating tables and control cabinet fronts. The installation happens via the back. The Panel PC is provided with a fixing technique with not losable screws that allows an easy connection with a crosstip screwdriver.
  • Page 25: Installation Of The Cfast Card

    VIPA HMI Deployment Panel PC Installation of the CFast card Connect power supply For the cabling of the power supply DC 12-30V a green plug is used. The connector is a plug with screw contacts. The plug has the following assignment: DC 24V DC 0V PE Protective earth...
  • Page 26: Commissioning

    VIPA HMI Deployment Panel PC Commissioning > Firmware update 3.3 Commissioning CAUTION! – Before commissioning the device must be brought to room tempera- ture. – At condensation the device must be absolutely dry before connected to power. – To avoid overheat during operation the device must not be laid open to direct sun light.
  • Page 27: Startup-Manager

    VIPA HMI Deployment Panel PC Commissioning > Startup-Manager 3.3.2 Startup-Manager Start screen As soon as the Panel PC is provided by power supply, the Startup-Manager will be loaded. At the first startup of the Startup-Manager the following start screen appears. There is a button on the initial screen with a counter, which counts backwards.
  • Page 28 VIPA HMI Deployment Panel PC Commissioning > Startup-Manager Autostart With [Autostart] you define which runtime and which project will be started automatically together with the panel startup. With [...] at ‘Runtime path’ res. ‘Project path’ all existing runtimes res. projects on the panel and the storage media will be listed.
  • Page 29 VIPA HMI Deployment Panel PC Commissioning > Startup-Manager With ‘Copy’ [...] files can be copied on the panel from a source path to a destination path. With ‘Autostart’ you can select the automatic startup of the Movicon-TCP upload server, the VNC server und the Startup-Manager. With [Back] you can return to the select menu.
  • Page 30: Connection To A Plc System

    VIPA HMI Deployment Panel PC Connection to a PLC system 3.4 Connection to a PLC system Overview For the inclusion into your PLC system several HMI/SCADA project-engineering plat- forms are at your disposal that has to be installed at an external PC. Here you may create your project, where appropriate simulate it and transfer it to the Panel PC that you’ve entered before.
  • Page 31: Operating System Windows Embedded Standard 7

    VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > General 3.5 Operating system Windows Embedded Standard 7 3.5.1 General Ò Windows Embedded Standard 7 - WES7 - delivers all the power, familiarity, and relia- bility of the Windows 7 operating system in a componentized form. Features ftp-Server and IIS-Webserver File viewer for Word and Excel...
  • Page 32: Structure

    VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure 3.5.2 Structure Icon Via icons on the desktop you gain direct access to the application related to the icon. Ò Desktop The desktop is the screen that is shown after login at Windows .
  • Page 33 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure Network connection As soon as your Panel PC is connected via Ethernet you can see here the Ethernet address. If there is no connection via Ethernet, the symbol is displayed crossed out.
  • Page 34 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure Control Panel The description of the Control Panel components relevant for operating the Panel PC can be found in the following: Change display language Per default, the PC is delivered with the display language "English". You can change the language in ‘Start è...
  • Page 35 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure In the opening dialog window check the box ‘User must enter a user name and password to use this computer.’ and confirm with [Apply]. You can also change the password in this section under [Reset Password] at any time.
  • Page 36 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure The next start-up takes place without requesting the log-in data. Enhanced Write Filter The ‘Enhanced Write Filter’ is a tool which can be used to disable permanent writing accesses to the internal drive "C:".
  • Page 37: Bios Setup

    VIPA HMI BIOS setup Overview BIOS setup 4.1 Overview In this chapter you will find information, required for calling the BIOS setup and the possible settings. The BIOS (Basic Input and Output System) setup program is a menu driven utility that enables you to make changes to the system configuration and tailor your system to suit your individual work needs.
  • Page 38: Main

    VIPA HMI BIOS setup Main Legends Function ßà Moves the highlight left or right to select a menu áâ Moves the highlight up or down between submenus or fields Exits the BIOS setup utility Scrolls forward or backward through the values or options of the highlighted field Tabulator Selects a field...
  • Page 39: Advanced

    VIPA HMI BIOS setup Advanced Intel RC Version Display the Intel Reference Code version. System Date The date format is day month/date/year an. Day displays a day, from Monday to Sunday. Month displays the month, from January to December. Date displays the date, from 1 to 31. Year displays the year, from 1999 to 2099.
  • Page 40 VIPA HMI BIOS setup Advanced Submenu "CPU Configura- This section is used to configure the CPU. tion" Hyper-Threading This field is used to enable or disable hyper-threading. Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks. Enabled - Permit the switching on of the execute disable function by the OS.
  • Page 41 VIPA HMI BIOS setup Advanced SATA Controller(s) Enables or disables SATA controller. Configure SATA as Configures the SATA as IDE or AHCI mode. - This option configures the serial ATA drives as parallel ATA physical storage device. AHCI - This option configures the serial ATA drives to use AHCI (AdvancedHost Con- troller Interface).
  • Page 42 VIPA HMI BIOS setup Advanced Legacy USB Support Due to the limited space of the BIOS ROM, the support for legacy USB keyboard (in DOS mode) is by default set to disabled. With more BIOS ROM space available, it will be able to support more advanced features as well as provide compatibility to a wide variety of peripheral devices.
  • Page 43 VIPA HMI BIOS setup Advanced Serial Port Enables or disables the serial port. Disabled - Serial port is not available Enabled - (default) Serial port is available Change Settings Selects an optimal setting for the super IO device. Onboard Serial Port 1 This field is used to configure the mode of serial port 1 as RS232, RS422 (default), Mode RS485 or RS485 AUTO.
  • Page 44: Chipset

    VIPA HMI BIOS setup Chipset 4.4 Chipset This section is used to configure the system based on the specific features of the chipset. CAUTION! Setting incorrect field values may cause the system to malfunction. Host Bridge Display the memory information. Ò...
  • Page 45 VIPA HMI BIOS setup Chipset IGFX-Boot Type This field is used to configure which video device will be activated during POST. This has no effect if external graphics present. The options are CRT, LVDS, DP-LVDS + CRT. Backlight Control Select The available options are ‘Pyroelectric sensor’...
  • Page 46 VIPA HMI BIOS setup Chipset Backlight Adjust the brightness of the backlight. Fixed Graphics Memory This field is used to configure the memory size of the fixed graphics, the options are Size 128MB and 256MB. Submenu "South Bridge" This field is used to configure the south bridge chipset. Azalia Controller This section disables Azalia or enables HD Audio.
  • Page 47: Boot

    VIPA HMI BIOS setup Boot 4.5 Boot This section is used to configure the boot features. Setup Promt Timeout This section configures the number of seconds to wait for the setup activation key. Bootup NumLock State This allows you to determine the default state of the numeric keypad. On - (default) The function of the numeric keypad is the number keys.
  • Page 48: Security

    VIPA HMI BIOS setup Security 4.6 Security If ONLY the Administra- If only the Administrator's password is set, then this only limits access to setup and is only tor's password is set asked for when entering setup. If ONLY the User's pass- If only the User's password is set, then this is a power on password and must be entered word is set to boot or enter setup.
  • Page 49: Save And Exit

    VIPA HMI BIOS setup Save and exit 4.7 Save and exit Save Changes and Exit To save the changes and exit the setup utility, select this field then press [Enter]. A dialog box will appear. Confirm by selecting [Yes]. You can also press [F4] to save and exit setup. Discard Changes and Exit To exit the Setup utility without saving the changes, select this field then press [Enter].
  • Page 50 VIPA HMI BIOS setup Save and exit Save as User Defaults To use the current configurations as user default settings for the BIOS, select this field then press [Enter]. A dialog box will appear. Confirm by selecting [Yes]. Restore User Defaults To restore the BIOS to user default settings, select this field then press [Enter].
  • Page 51: Installation Guidelines

    VIPA HMI Installation guidelines Basic rules for the EMC-equitable assembly of installations Installation guidelines 5.1 Basic rules for the EMC-equitable assembly of installations General The installation guidelines contain information about the interference free deployment of a PLC system. There is the description of the ways, interference may occur in your PLC, how you can make sure the electromagnetic compatibility (EMC), and how you manage the isolation.
  • Page 52 VIPA HMI Installation guidelines Basic rules for the EMC-equitable assembly of installations Coupling mechanism Cause Typical source Capacitate coupling Capacitate or electric coupling occurs Interference through parallel signal between conductors with different lines potential. The coupling is propor- Static discharge of the personnel tionate to the temporal change of the Contactors voltage.
  • Page 53 VIPA HMI Installation guidelines Basic rules for the EMC-equitable assembly of installations Proof the correct fixing of the lead isolation. – Data lines must be laid isolated. – Analog lines must be laid isolated. When transmitting signals with small ampli- tudes the one sided laying of the isolation may be favourable.
  • Page 54: Emc-Equitable Assembly

    VIPA HMI Installation guidelines EMC-equitable assembly 5.2 EMC-equitable assembly Mostly, measures for suppressing interference voltages are only taken, when the control is already in commission and the perfect receive of a wanted signal is disturbed. Causes for such interference's are in the most cases inadequate reference potentials, coming from mistakes at the device assembly and installation.
  • Page 55: Emc-Equitable Cabling

    VIPA HMI Installation guidelines EMC-equitable cabling 5.3 EMC-equitable cabling Line routing Content of this section is the line routing of bus, signal and supply lines. Object of the line routing is to suppress the "slurring" at parallel lines. Line routing inside and For an EMC-equitable routing of the lines it is convenient to divide the cables in different outside of cubicles groups and install each group itself:...
  • Page 56 Install these protective elements at the location where the cables enter the building. Any lightning protection system must be based on an individual assess- ment of the entire plant. For questions please contact YASKAWA Europe GmbH. Equipotential bonding Potential differences can occur between different sections when controllers and periph-...
  • Page 57 VIPA HMI Installation guidelines EMC-equitable cabling Avoid cables with foil-type screens as the foil can be easily damaged by tension and pressure at the point of attachment; this can result in reduced effectiveness of the screening action. As a rule you should always ground the screens of cables on both ends. This is the only way in which you can ensure that high frequency interference is attenuated prop- erly.
  • Page 58: Special Precautions Providing High Noise Immunity

    VIPA HMI Installation guidelines Special precautions providing high noise immunity 5.4 Special precautions providing high noise immunity Inductors require snubber Inductors controlled by your programmable controller (e.g. contactors and relays) do not networks normally require additional snubber networks or suppressors as the respective modules have been provided with the required components.
  • Page 59: Checklist For The Emc-Compliant Installation Of Controllers

    VIPA HMI Installation guidelines Checklist for the EMC-compliant installation of controllers 5.5 Checklist for the EMC-compliant installation of controllers EMC-measures Space for Notes Connection of the inactive parts You should take special care to check the connections of: Module racks Frames Screen and protected earth conductor Are all the inactive metal parts interconnected by means of large-surface and low-...

This manual is also suitable for:

67p-pnl0Vipa ppc015 es67p-pnl0-jx

Table of Contents