  • Page 1 VIPA HMI PPC | 67K-PNL0 | Manual HB160 | PPC | 67K-PNL0 | GB | 16-40 Panel PC - PPC010 ES...
  • Page 2 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 Email: info@vipa.com Internet: www.vipa.com 67K-PNL0_000_PPC010ES,1,GB - © 2016...
  • Page 3: Table Of Contents

    VIPA HMI Table of contents Table of contents General..................4 1.1 Copyright © VIPA GmbH ........... 4 1.2 About this manual.............. 5 1.3 Safety information.............. 6 Hardware description.............. 8 2.1 Safety information for users..........8 2.2 Properties................9 2.3 Structure................10 2.3.1 Overview...............
  • Page 4: General

    General VIPA HMI Copyright © VIPA GmbH General 1.1 Copyright © VIPA GmbH All Rights Reserved This document contains proprietary information of VIPA and is not to be disclosed or used except in accordance with applicable agree- ments. This material is protected by the copyright laws. It may not be repro- duced, distributed, or altered in any fashion by any entity (either internal or external to VIPA), except in accordance with applicable agreements, contracts or licensing, without the express written con-...
  • Page 5: About This Manual

    VIPA HMI General About this manual Trademarks VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V, System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbH. SPEED7 is a registered trademark of profichip GmbH. SIMATIC, STEP, SINEC, TIA Portal, S7-300 and S7-400 are regis- tered trademarks of Siemens AG.
  • Page 6: Safety Information

    General VIPA HMI Safety information Structure of the manual The manual consists of chapters. Every chapter provides a self-con- tained description of a specific topic. Guide to the document The following guides are available in the manual: An overall table of contents at the beginning of the manual References with page numbers Availability The manual is available in:...
  • Page 7 VIPA HMI General Safety information Documentation The manual must be available to all personnel in the project design department installation department commissioning operation CAUTION! The following conditions must be met before using or commissioning the components described in this manual: –...
  • Page 8: Hardware Description

    Hardware description VIPA HMI Safety information for users Hardware description 2.1 Safety information for users Handling of electro- VIPA modules make use of highly integrated components in MOS- static sensitive modules Technology. These components are extremely sensitive to over-vol- tages that can occur during electrostatic discharges. The following symbol is attached to modules that can be destroyed by electrostatic discharges.
  • Page 9: Properties

    VIPA HMI Hardware description Properties 2.2 Properties General The VIPA Panel PC is a combination of industrial PC with state of the art performance features and a touch panel with ideal display capabil- ities. The Panel PC is a compact and modular embedded PC based Ò...
  • Page 10: Structure

    Hardware description VIPA HMI Structure > Overview 2.3 Structure 2.3.1 Overview Front view Slot for voltage supply (DC 12-30V) VGA interface Reset button RS232/RS422/RS485 interface COM 2 RS232/RS422/RS485 interface COM 1 4x"Host"-USB-A interface RJ45 jack for Ethernet communication LAN 2 RJ45 jack for Ethernet communication LAN 1 3.5mm Audio Line out 10 Power switch (pushbutton)
  • Page 11 VIPA HMI Hardware description Structure > Overview Bottom view 1 Slot for voltage supply (DC 12-30V) 2 VGA interface 3 Reset button 4 RS232/RS422/RS485 interface COM 2 5 RS232/RS422/RS485 interface COM 1 6 4x"Host"-USB-A interface 7 RJ45 jack for Ethernet communication LAN 2 8 RJ45 jack for Ethernet communication LAN 1 9 3.5mm Audio Line out Please make sure that the Panel PC always has to be...
  • Page 12: Interfaces

    Hardware description VIPA HMI Structure > Interfaces The Panel PC starts automatically when the power supply is switched on. But you can change the configuration in the BIOS setup so that the Panel PC has to be switched off by Ä...
  • Page 13 VIPA HMI Hardware description Structure > Interfaces RS422 interface Logical conditions as voltage difference between 2 twisted lines Serial bus connection full-duplex four-wire operation Line length: 250m at 115.2kbit/s ... 1200m at 19.2kbit/s Data transfer rate up to 115.2kbit/s RS485 interface Logical conditions as voltage difference between 2 twisted lines Serial bus connection half-duplex two-wire operation Line length: 250m at 115.2kbit/s ...
  • Page 14 Hardware description VIPA HMI Structure > Interfaces HB160 | PPC | 67K-PNL0 | GB | 16-40...
  • Page 15: Memory Management

    VIPA HMI Hardware description Structure > Memory management VGA interface VGA SubD HD15 jack to connect a second display. Line out 3.5 mm stereo jack to connect an active speaker system or an ear- phone. "Host"-USB-A Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be connected.
  • Page 16: Dimensions

    Hardware description VIPA HMI Dimensions Slot for CFast At the back of the Panel PC there is a card slot for a memory card. At this slot you can plug storage modules of the type CFast 2.0 - 600 MB/s (6GBit/s) - SATA protocol - not hot-swap compatible. Assignment Assignment n.c.
  • Page 17 VIPA HMI Hardware description Dimensions Installation dimensions For the installation of the Panel PC in control cabinets and desks the following dimensions are necessary: 10.1" - 67K-PNL0-... Front panel thickness 3 ... 12mm Installation cutting (W x H) 297 x 212mm Front panel (W x H x T) 308 x 223 x 6.70mm Rear panel (W x H x D)
  • Page 18: General Data

    Hardware description VIPA HMI General data 2.5 General data Conformity and approval Conformity 2014/35/EU Low-voltage directive 2014/30/EU EMC directive Approval Refer to Technical Data others RoHS 2011/65/EU Product is lead-free; Restriction of the use of certain hazardous substances in electrical and electronic equipment Protection of persons and device protection Type of protection...
  • Page 19: Technical Data

    VIPA HMI Hardware description Technical data > 67K-PNL0-JB Mounting conditions Mounting place In the control cabinet Mounting position Horizontal and vertical Standard Comment Emitted interfer- EN 61000-6-4 Class A (Industrial area) ence Noise immunity EN 61000-6-2 Industrial area zone B EN 61000-4-2 8kV at air discharge (degree of severity 3), 4kV at contact discharge (degree of severity...
  • Page 20 Hardware description VIPA HMI Technical data > 67K-PNL0-JB Order no. 67K-PNL0-JB Processor Intel Atom Dualcore 1.86 GHz Operating system Windows embedded Standard 7 User software Movicon 11 Win Standard Work memory 2 GB User memory 16 GB Available memory (user data) 7 GB SD/MMC Slot CF Card Slot Typ II...
  • Page 21 VIPA HMI Hardware description Technical data > 67K-PNL0-JB Order no. 67K-PNL0-JB Ethernet connector 2 x RJ45 Integrated ethernet switch Video connectors VGA SubD HD15 Audio connections Line out, stereo jack 3.5 mm Technical data power supply Power supply (rated value) DC 24 V Power supply (permitted range) DC 20.4...28.8 V...
  • Page 22: Pnl0-Jx

    Hardware description VIPA HMI Technical data > 67K-PNL0-JX Order no. 67K-PNL0-JB UL certification KC certification 2.6.2 67K-PNL0-JX Order no. 67K-PNL0-JX Type Panel PC PPC021 ES Display Display size (diagonal) 10.1 " Display size (width) 217 mm Display size (height) 136 mm Resolution 1280 x 800 / 800 x 1280 Aspect ratio...
  • Page 23 VIPA HMI Hardware description Technical data > 67K-PNL0-JX Order no. 67K-PNL0-JX Touch function Dual Touch Keyboard external via USB Mouse external via USB Interfaces MPI, PROFIBUS-DP MPI, PROFIBUS-DP connector Serial, COM1 RS232 / RS422 / RS485 COM1 connector Sub-D, 9-pin, male Serial, COM2 RS232 / RS422 / RS485 COM2 connector...
  • Page 24 Hardware description VIPA HMI Technical data > 67K-PNL0-JX Order no. 67K-PNL0-JX Mounting via integrated pivoted lever Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 308 mm x 223 mm x 6.7 mm Rear panel 292 mm x 207 mm x 54.2 mm Installation cut-out Width...
  • Page 25: Deployment Panel Pc

    VIPA HMI Deployment Panel PC Installation Deployment Panel PC 3.1 Installation Overview The Panel PC is suitable for the installation in operating tables and control cabinet fronts. The installation happens via the back. The Panel PC is provided with a fixing technique with not losable screws that allows an easy connection with a crosstip screwdriver.
  • Page 26: Installation Of The Cfast Card

    Deployment Panel PC VIPA HMI Installation of the CFast card Connect power supply For the cabling of the power supply DC 12-30V a green plug is used. The connector is a plug with screw contacts. The plug has the fol- lowing assignment: DC 24V DC 0V...
  • Page 27: Commissioning

    VIPA HMI Deployment Panel PC Commissioning > VIPA Startup-Manager 3.3 Commissioning CAUTION! – Before commissioning the device must be brought to room temperature. – At condensation the device must be absolutely dry before connected to power. – To avoid overheat during operation the device must not be laid open to direct sun light.
  • Page 28 Deployment Panel PC VIPA HMI Commissioning > VIPA Startup-Manager Selection menu There are following buttons in the selection menu: Settings Info/Update Autostart Backup Exit Back Settings In [Settings] under ‘Change Settings’ you can set a password for the Startup-Manager. The password will be requested when inter- rupting the start countdown.
  • Page 29 VIPA HMI Deployment Panel PC Commissioning > VIPA Startup-Manager After the successful update a message appears. Confirm with [OK] to complete the update. ð The Panel PC restarts. Autostart With [Autostart] you define which runtime and which project will be started automatically together with the panel startup.
  • Page 30: Connection To A Plc System

    Deployment Panel PC VIPA HMI Connection to a PLC system You can optionally set parameters. Exit with [Finish]. With ‘Copy’ [...] files can be copied on the panel from a source path to a destination path. With ‘Autostart’ you can select the automatic startup of the Movicon-TCP upload server, the VNC server und the VIPA Startup-Manager.
  • Page 31: Operating System Windows Embedded Standard 7

    VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > General 3.5 Operating system Windows Embedded Standard 7 3.5.1 General Ò Windows Embedded Standard 7 - WES7 - delivers all the power, familiarity, and reliability of the Windows 7 operating system in a com- ponentized form.
  • Page 32: Structure

    Deployment Panel PC VIPA HMI Operating system Windows Embedded Standard 7 > Structure Pen entry You’re operating the Panel by means of a pencil for capacitive touch screen res. with the finger. When touching an area at the touch screen this area is recognized and the program reacts accordingly. The following types of entry are differentiated: Double click A double click has to be executed like mouse operation by...
  • Page 33 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure Icon Via icons on the desktop you gain direct access to the application related to the icon. Desktop Ò The desktop is the screen that is shown after login at Windows It contains e.g.
  • Page 34 Deployment Panel PC VIPA HMI Operating system Windows Embedded Standard 7 > Structure Expanded Software Via ‘Tools è Show expanded keyboard’ you may open the expanded Keyboard keyboard. Control Panel The description of the Control Panel components relevant for oper- ating the Panel PC can be found in the following: Change display language Per default, the PC is delivered with the display language "Eng-...
  • Page 35 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure System properties Via ‘Start è Settings è System and Security è System’ you Ò receive information about the version of the current Windows operating system and the copyright. Via ‘System Protection’...
  • Page 36 Deployment Panel PC VIPA HMI Operating system Windows Embedded Standard 7 > Structure At the next start-up the user has to select the user name and enter the ‘Password’ . Enable automatic log-in Type "cmd" under ‘Start è Run’. In the next window type "control userpasswords2". In the opening dialog window uncheck the box ‘User must enter a user name and password to use this computer.’...
  • Page 37 VIPA HMI Deployment Panel PC Operating system Windows Embedded Standard 7 > Structure Enhanced Write Filter The ‘Enhanced Write Filter’ is a tool which can be used to disable permanent writing accesses to the internal drive "C:". It can be written to the drive but the data is not stored permanently.
  • Page 38: Bios Setup

    BIOS setup VIPA HMI Overview BIOS setup 4.1 Overview In this chapter you will find information, required for calling the BIOS setup and the possible settings. The BIOS (Basic Input and Output System) setup program is a menu driven utility that enables you to make changes to the system configuration and tailor your system to suit your individual work needs.
  • Page 39: Main

    VIPA HMI BIOS setup Main Powering on the computer and immediately pressing [Del] allows you to enter Setup. Selection boot medium Powering on the computer and immediately pressing [F7] allows you, as long as the loading screen is shown, to change to the boot medium selection.
  • Page 40: Advanced

    BIOS setup VIPA HMI Advanced Intel RC Version Display the Intel Reference Code version. System Date The date format is day month/date/year an. Day displays a day, from Monday to Sunday. Month displays the month, from January to December. Date displays the date, from 1 to 31. Year displays the year, from 1999 to 2099.
  • Page 41 VIPA HMI BIOS setup Advanced Launch LAN1/2 PXE Enables or disables the boot option for legacy network devices con- OpROM nected to LAN1 or LAN2. Disabled - Starts no PXE OpROM Enabled - Starts the PXE OpROM, to be able to boot about PXE Submenu "CPU Config- This section is used to configure the CPU.
  • Page 42 BIOS setup VIPA HMI Advanced Limit CPUID Maximum The CPUID instruction of some newer CPUs will return a value greater than 3. The default is disabled because this problem does not exist in the Windows series operating systems. If you are using an operating system other than Windows, this problem may occur.
  • Page 43 VIPA HMI BIOS setup Advanced Legacy USB Support Due to the limited space of the BIOS ROM, the support for legacy USB keyboard (in DOS mode) is by default set to disabled. With more BIOS ROM space available, it will be able to support more advanced features as well as provide compatibility to a wide variety of periph- eral devices.
  • Page 44 BIOS setup VIPA HMI Advanced Serial Port Enables or disables the serial port. Disabled - Serial port is not available Enabled - (default) Serial port is available Change Settings Selects an optimal setting for the super IO device. Onboard Serial Port 0 This field is used to configure the mode of serial port 0 as RS232 Mode (default), RS422, RS485 or RS485 AUTO.
  • Page 45: Chipset

    VIPA HMI BIOS setup Chipset Change Settings Selects an optimal setting for the super IO device. Onboard Serial Port 1 This field is used to configure the mode of serial port 1 as RS232, Mode RS422 (default), RS485 or RS485 AUTO. Terminal resistor Enables or disables the terminal resistor for RS422 and RS485.
  • Page 46 BIOS setup VIPA HMI Chipset CAUTION! Setting incorrect field values may cause the system to malfunction. Host Bridge Display the memory information. Ò Ò Submenu "Intel This section is used to configure the Intel IGD graphic configuration. Configuration" IGFX-Boot Type This field is used to configure which video device will be activated during POST.
  • Page 47 VIPA HMI BIOS setup Chipset Backlight On/Off Please configure this option only when changing the panel, otherwise Reverse the display may not work. Backlight Dimming The options are ‘Tact Switch’ , ‘Manual’ and ‘Light Sensor’ . The Control Select default setting is ‘Manual’ and the Backlight option below will be con- figurable.
  • Page 48: Boot

    BIOS setup VIPA HMI Boot 4.5 Boot This section is used to configure the boot features. Setup Promt Timeout This section configures the number of seconds to wait for the setup activation key. Bootup NumLock State This allows you to determine the default state of the numeric keypad. On - (default) The function of the numeric keypad is the number keys.
  • Page 49: Security

    VIPA HMI BIOS setup Security 4.6 Security If ONLY the Administra- If only the Administrator's password is set, then this only limits access tor's password is set to setup and is only asked for when entering setup. If ONLY the User's pass- If only the User's password is set, then this is a power on password word is set and must be entered to boot or enter setup.
  • Page 50: Save And Exit

    BIOS setup VIPA HMI Save and exit 4.7 Save and exit Save Changes and Exit To save the changes and exit the setup utility, select this field then press [Enter]. A dialog box will appear. Confirm by selecting [Yes]. You can also press [F4] to save and exit setup. Discard Changes and To exit the Setup utility without saving the changes, select this field Exit...
  • Page 51 VIPA HMI BIOS setup Save and exit Save as User Defaults To use the current configurations as user default settings for the BIOS, select this field then press [Enter]. A dialog box will appear. Confirm by selecting [Yes]. Restore User Defaults To restore the BIOS to user default settings, select this field then press [Enter].
  • Page 52: Installation Guidelines

    Installation guidelines VIPA HMI Basic rules for the EMC-equitable assembly of installations Installation guidelines 5.1 Basic rules for the EMC-equitable assembly of installations General The installation guidelines contain information about the interference free deployment of a PLC system. There is the description of the ways, interference may occur in your PLC, how you can make sure the electromagnetic compatibility (EMC), and how you manage the isolation.
  • Page 53 VIPA HMI Installation guidelines Basic rules for the EMC-equitable assembly of installations Coupling mechanism Cause Typical source Galvanic coupling Galvanic or metallic coupling Pulsed devices (Net influ- always occurs, when two cur- ence from transducers and rent circuits have a common foreign net devices) line.
  • Page 54: Emc-Equitable Assembly

    Installation guidelines VIPA HMI EMC-equitable assembly Basic rules for EMC In the most times it is enough to take care of some elementary rules to guarantee the EMC. Please regard the following basic rules when installing your PLC. Take care of a correct area-wide grounding of the inactive metal parts when installing your components.
  • Page 55: Emc-Equitable Cabling

    VIPA HMI Installation guidelines EMC-equitable cabling Guidelines for assem- When assembling the devices, you have to ensure the large-surface bling and grounding of grounding of the inactive metal parts. A correctly done grounding sup- inactive metal parts ports an unambiguous reference potential for the control and reduces the impact of coupled interferences.
  • Page 56 Installation guidelines VIPA HMI EMC-equitable cabling Group C unshielded lines for direct and alternating voltage >400V Group D Lines for H1 respectively TCP/IP Combination of groups Following the table you may see the conditions for the cabling of the line groups by combining the single groups: Group A Group B Group C...
  • Page 57 VIPA HMI Installation guidelines EMC-equitable cabling Lightning protection CAUTION! Where cables and signal lines for PLC equipment are installed outside of buildings, the conditions for internal and external lightning protection must be satisfied. – Exterior lines should either be installed in metallic conduit pipes that is grounded on both ends or in steel-reinforced concrete cable trunks with continu- ously connected reinforcing.
  • Page 58 Installation guidelines VIPA HMI EMC-equitable cabling Screening of lines and Screening is one method commonly used to reduce (attenuate) the cables interference pick-up from magnetic, electrical or electromagnetic fields. Interference on screens is conducted to ground by the conductive connection between the screen and the screening rain/enclosure. To avoid interference from these currents it is very important that the neutral connection is a low-impedance connection.
  • Page 59: Special Precautions Providing High Noise Immunity

    VIPA HMI Installation guidelines Special precautions providing high noise immunity 5.4 Special precautions providing high noise immunity Inductors require Inductors controlled by your programmable controller (e.g. contactors snubber networks and relays) do not normally require additional snubber networks or suppressors as the respective modules have been provided with the required components.
  • Page 60 Installation guidelines VIPA HMI Special precautions providing high noise immunity Suppression of fluores- cent lamps in cubicles 1 Fluorescent lamp 2 Screen above the lamp 3 Screened cable 4 Switch with metallic cover 5 Line filter or screened power cable HB160 | PPC | 67K-PNL0 | GB | 16-40...
  • Page 61: Checklist For The Emc-Compliant Installation Of Controllers

    VIPA HMI Installation guidelines Checklist for the EMC-compliant installation of controllers 5.5 Checklist for the EMC-compliant installation of controllers EMV-measures Space for Notes Connection of the inactive parts You should take special care to check the connections of: Module racks Frames Screen and protected earth conductor Are all the inactive metal parts interconnected by means of large-sur-...