Repair

Repair Kit 245876 is available. Parts included with
the kit are marked with *.
Disassembly
1.
Follow Pressure Relief Procedure, page 6.
Engage trigger lock.
2.
Disconnect fluid hose. Remove tip and tip guard
(17).
17
3.
Using a wrench, remove cap (10) with spring (9)
(releases spring tension on needle).
4.
Remove valve seat (2*) and gasket (12*).
12*
2*
12
10
9
T12180A
T12180A
T12181A
5.
Holding needle with tool (A*), remove needle
retainer (8).
A*
6.
Pull needle (3*) out the front of the gun.
3*
7.
Using a socket wrench, remove seal retainer (4*)
from the back of the gun. Use a pick to remove
gasket (11*).
8.
Clean and replace parts as needed.
Repair
8
T12188A
T12183A
4*
11*
T12186A
309523D