Important: Read all instructions prior to installation.
LED Parking Lot/Area Light
ALD-50K10W-C-BRC3-SF
Specifications
Environmental Specifications
Operating Temperature
IP Rating
Wiring Diagram
120–277 / 277–480 VAC Input
Line
L
Neutral
N
Ground
GND
Mounting Options
Dim (+)
+
Dim (-)
Slip-Fitter (ALD-SF)
-
Flush Mount (ALD-FM)
-22°–131° F (-30°–55° C)
IP65
Black
L
White
N
Green
GND
Purple
+
Gray / Pink
Slip-Fitter with Junction Box (ALD-SFS)
-
Yoke Mount (ALD-FB)
Safety and Notes
• Product should be installed and serviced by a certified electrician
in accordance with applicable national, state, and local building
and electrical codes.
• To reduce the risk of electric shock, ensure that the main power
source and circuit breakers are switched off before performing
any installation or wiring procedures.
• Avoid looking directly into lamp when illuminated.
• Ensure all mounts are securely attached and will support the
weight of the fixture. Failure to properly support fixture may
result in damage or injury, for which the manufacturer does not
assume responsibility.
Check product label for specific electrical
specifications related to installation.
Line
Improper installation will void warranty.
L
L
Neutral
N
N
Ground
GND
GND
1–10 V Dimming
Dim (+)
+
+
Dim (-)
-
-
Rev Date: V3 05/03/2023