Important: Read all instructions prior to installation.
LED Parking Lot/Area Light
PLLD-S150K240-HP(SF)
Specifications
Environmental Specifications
Operating Temperature
IP Rating
Wiring Diagram
Line
Neutral
Ground
Included Slip-Fitter Mount Installation
Dim (+)
1. With supply power off, connect wiring.
Dim (-)
2. Slide mount over pole/post and secure in place.
Note: The maximum pole/post diameter is 2.5 in.
3. Rotate light to desired angle and tighten adjustment screw.
Additional Mounting Options
Adjustable Square/Round Pole Mount (PLLD-S1APM)
-40°–113° F(-40°–45° C)
IP65
120–277 VAC Input
L
L
N
N
GND
GND
Purple
+
+
-
-
Fixed Square/Round Pole Mount (PLLD-S1FPM)
Safety and Notes
• Product should be installed and serviced by a certified electrician in accordance
with applicable national, state, and local building and electrical codes.
• To reduce the risk of electric shock, ensure that the main power source and
circuit breakers are switched off before performing any installation or wiring
procedures. Do not install while inclement weather, such as rain storms, may
increase the chances of electrical hazard.
• Avoid looking directly into lamp when illuminated.
• Ensure all mounts are securely attached and will support the weight of the
fixture. Failure to properly support fixture may result in damage or injury, for
which the manufacturer does not assume responsibility.
Check product label for specific electrical
Line
specifications related to installation.
Improper installation will void warranty.
Neutral
Ground
Dim (+)
Black
Dim (-)
White
Green
AC input wires
Gray
Rev Date: V1 10/05/2021
Angle Locking
4400 Earth City Expy, St. Louis, MO 63045
bolt
User Manual
PLLD-S1 Series
Slip fitter
Black
L
L
White
N
N
Green
GND
GND
0–10 V Dimming
Purple
square/rou
+
+
Gray
-
-
Locking bolt
fixed squa
Wall/Trunnion Mount (PLLD-S1WM)
trunnion