Installation; General Mounting Considerations; Lifting - Gardner Denver DRUM XK Series Installation Operating & Maintenance Manual

Screw compressor
Table of Contents

Advertisement

3
CAUTION
Do not lift using other parts of
the machine.
4990140010 Date:03/15

Installation

3.1
General
When selecting the machine mounting position, the following points should
be considered:
• Access to oil ll/level and drain plugs
• Adequate clearance to allow the cooling air to circulate around the
machine
• Install away from sources of heat, e.g. vehicle exhaust air or hot pipes that
could e ect the compressor temperature in any way.
• Venting relief/control valve air must be unobstructed and direct to the
atmosphere.
• Fit the relief and/or protection valve control valves as close as possible to
the XK12 discharge port.
• Venting valves must be positioned so that hot air cannot vent onto the
operator or the compressor
• Silencers should be tted as close as possible to the discharge port.
For the recommended layout of the machine and ancillaries, see gure 1.
3.2

Lifting

- see g. 3
The weight of the basic compressor without ancillaries is 120 kg.
The mounting face to which the basic machine is tted should be at to
avoid distortion/stress and mounting bolts/locking nuts should be M16,
grade 8.8 or higher.
The basic compressor is supplied with an eyebolt attached for lifting. When
the machine has been installed, the eyebolt should be removed and replaced
by the blanking grommet (supplied) tted to the cover.
Any equipment used for lifting should be rated accordingly.
Figure 3. Lifting
XK12 Installation, Operating & Maintenance Manual
XK12 Installation, Operating & Maintenance Manual
Page 7