SECTION 2
INSTALLATION
GENERAL - On receipt of the unit, check for any damage that may have been incurred during transit. Report
any damage or missing parts as soon as possible.
Do not electric weld on the compressor or base; bearings can be damaged by
passage of current.
LIFTING UNIT - Proper lifting and/or transporting methods must be used to prevent damage. Lifting slots are
provided in the base for tow motor use. The unit may also be moved into location by rolling on bars.
Lift compressor package by base only. Do not use other places such as
motors, compressors or discharge manifold piping as lifting points.
The eyebolts or lugs provided on the motors are for lifting the motors only and
should not be used to lift any additional weight. All eyebolts must be securely
tightened. When lifting the motors, the lifting angle must not exceed 15
degrees. Failure to observe this warning may result in damage to equipment or
personal injury.
Compressor, air/oil reservoir, separator chamber and all piping and tubing may
be at high temperature during and after operation.