Sartorius BL150S Instruction Manual

Hide thumbs Also See for BL150S:

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Sartorius / B. Braun BL150S at our website:

Advertisement

Table of Contents
loading

Summary of Contents for Sartorius BL150S

  • Page 1 (217) 352-9330 | Click HERE Find the Sartorius / B. Braun BL150S at our website:...
  • Page 2 INSTRUCTION MANUAL Balance Model : BL310 Brand :...
  • Page 3 98648-008-55 lite Sartorius Basic Series lite Sartorius Gem Series Electronic Precision Balances and Precious Metal Scales Operating Instructions...
  • Page 4: Table Of Contents

    The Basic Series and Gem Series Practical Use ........2 from Sartorius offer precision balances/ Contents ........2 scales with capacities ranging from Warning and Safety Information ..2 0.1 mg to 12 kg. Getting Started ........ 3...
  • Page 5: Getting Started

    Balance/ scale registration card, if available indicating W eighing pan the date of installation, and return the Pan support card to your Sartorius office or dealer. Shield ring Shield plate Storage and Shipping Conditions Dust cover Do not expose the balance/ scale to...
  • Page 6 Installation Instructions Conditioning the Balance/ Scale: Moisture in the air can condense Y our balance/ scale is designed to on the surfaces of a cold balance/ provide reliable weighing results under scale whenever it is brought into a normal ambient conditions. W hen substantially warmer place.
  • Page 7 Setting up the Balance/ Scale Balances/ Scales with an Analytical Draft Shield Chamber: Place the components listed below inside the chamber in the order given: Shield plate Shield ring Pan support W eighing pan Gem tray (only with model GC503) Balances/ Scales with a Glass Draft Shield: Place the components listed below inside the chamber in the order given:...
  • Page 8 Connecting the Balance/ Scale to AC Power/ Safety Precautions Use only original Sartorius AC adapters: for Europe: 6971948 for the R SA: 6971949 for the U.S.: 6971947 for Australia: 6971950 Insert the right-angle plug into the jack The AC adapter rated to Class 2 can be plugged...
  • Page 9 Selecting the Line Voltage (Mains Voltage) Use the following original AC adapters for selecting the line voltage: AC adapter TN G8, order no. 6971951 (universal) AC adapter TN G8, order no. 6971952 (for the U.K.) Use the switch to toggle between 230 V and 115 V Leveling the Balance/ Scale (only for models BL 210S, BL 120S, BL 60S, BL 150S, BL 1500S, GC503, GM1502)
  • Page 10: Operating The Balance/ Scale

    Operating the Balance/ Scale Basic Weighing Function Available Features T aring the balance/ scale You can tare the balance/ scale within the entire weighing range. Preparation T urn on the balance/ scale: Press e T o change configurations: See the chapter entitled Configuring the Balance/ Scale T o load factory-set configurations: See Configuring the Balance/ Scale, parameter 9...
  • Page 11: Calibration/ Adjustment

    Calibration/ Adjustment Always calibrate/ adjust the balance/ scale after setting it up in a new location. Available Features Calibration/ adjustment can only be performed when there is no load on the balance/ scale, the balance/ scale is tared, the internal signal is stable. If these conditions are not met, an error message is displayed.
  • Page 12: Application Programs

    Application Programs Counting Purpose W ith the Counting program you can determine the number of parts that each have approximately equal weight. Available Features Store the current weight value to have it loaded as the preset reference sample quantity next time you initialize the Counting application The reference sample quantity can be changed in the operating menu:...
  • Page 13 Example Determine an unknown piece count; weigh the preset reference sample quantity Settings (changes in the factory settings required for this example): Menu: Application program: Counting (menu code 2. 1. 4) R eference sample quantity: 20 pcs (menu code 3. 3. 3) Step Key (or instruction) Display/ Printout 11.
  • Page 14: Weighing In Percent

    Weighing in Percent Purpose This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight. Available Features Store the current weight value to have it loaded as the preset reference percentage next time you initialize the W eighing in Percent application The reference percentage can be changed in the operating menu:...
  • Page 15 Example Determine an unknown percentage; store the weight on the balance/ scale as a reference percentage Settings (changes in the factory settings required for this example): Menu: Application program: W eighing in percent (menu code 2. 1. 5) Menu: R eference percentage 100 % (menu code 3. 3. 5) Step Key (or instruction) Display/ Printout 11.
  • Page 16: Weigh Averaging

    Weigh Averaging Purpose Use this program to determine weights under unstable ambient conditions. In this program, the balance/ scale calculates the weight as the average value from a defined number of individual weighing operations. These weighing operations are also known as subweighing operations or subweighs. Available Features The measured result displayed is the arithmetic mean shown in the selected weight unit;...
  • Page 17 Example Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing operations. Settings (changes in the factory settings required for this example): Menu: Application program: W eigh Averaging (menu code 2. 1.12) Step Key (or instruction) Display/ Printout 1.
  • Page 18: N Et-T Otal Formulation/Second T Are Memory

    Net-T otal Formulation/ Second T are Memory W ith this application program you can weigh in components for formulation of a mixture. Preparation Configure the N et-T otal Formulation/ Second T are Memory application in the operating menu: See Configuring the Balance/ Scale Menu code 2.1.3 Example Step...
  • Page 19: T Oggle Between Weighing Units

    T oggle Between Weight Units W ith this application program you can toggle the display of a weight value back and forth between two weight units. Configure the T oggle W eight Units application in the operating menu: See Configuring the Balance/ Scale, menu code 2.1. 2 T oggle weight units lite (Factory setting on Gem models)
  • Page 20: Configuring The Balance/ Scale

    Configuring the Balance/ Scale Setting the Parameters (Menu Codes) lite lite Y ou can configure your Basic balance or Gem scale to meet individual requi- rements by selecting from the parameters available in the menu. Example: Adapt the balance/ scale to unstable ambient conditions: Menu code 1 1 4 Step Key (or instruction) Display...
  • Page 21: Balance/ Scale Operating Menu (Overview)

    Balance/ Scale Operating Menu (Overview) Factory setting User setting Menu 1. Balance/ 1.1. Adapt filter 1.1.1 Minimum vibration scale functions 1.1.2 N ormal vibration 1.1.3 Strong vibration 1.1.4 Extreme vibration 1.3. Stability range 1.3.1 1/ 4 digit 1.3.2 1/ 2 digit 1.3.3 1 digit 1.3.4...
  • Page 22: Error Codes

    The balance/ scale has not Calibrate/ adjust the balance/ is obviously wrong been calibrated/ adjusted scale The balance/ scale was not T are before weighing tared before weighing If any other errors occur, please contact your local Sartorius Service Center.
  • Page 23: Care And Maintenance

    Care and Maintenance Service R egular servicing by a Sartorius technician will extend the service life of your balance/ scale and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from 1 month to 2 years.
  • Page 24: Instructions For Recycling

    AC adapter no longer functions properly The AC adapter has been stored for a relatively long period under unfavorable conditions In this case, notify your nearest Sartorius Service Center or the International T echnical Support Unit based in Goettingen, Germany. Maintenance and repair work...
  • Page 25: Overview

    Overview Specifications Basic lite Series and Gem lite Series Model BL210S BL120S BL60S GC503 GM1205 W eighing capacity 505 ct/ 101 1200 R eadability 0.001 ct/ 0.2 T are range (subtractive) 505 ct/ 101 1200 R epeatability mg 0.1 0.001 ct/ 0.2 L inearity mg 0.2 0.002 ct/ 0.4...
  • Page 26 Basic Series and Gem Series lite lite Model BL150S BL1500S, BL610, BL310, GM212 BL150, BL6100, GM1502 GM612 GM312 GM152 GM6101 Weighing capacity 1500 6100 R eadability 0.001 0.01 0.01 0.01 0.01 0.01 T are range (subtractive) g 1500 6100 R epeatability g 0.0015 0.015...
  • Page 27 Basic lite und Gem lite Serie Model BL3100, BL1500 BL600, BL12 GM3101 GM601 W eighing capacity 3100 1500 12000 6000 3000 R eadability T are range (subtractive) 3100 1500 R epeatability L inearity Operating temperature range +40 C (263 313 K, 32 F 104 F) Sensitivity drift within +30 C / K 1 10...
  • Page 28: Accessories (Options)

    Accessories (Options) Product Order No. Product Order No. Interface port, installation kit Dust cover, for use during weighing for models with a for models with a rectangular readability 1mg YDO01BL weighing pan 6960BC02 for models BL 210S, BL 120S, for models with a round BL 60S, GC503 YDO02BL weighing pan...
  • Page 29: C Marking

    Important N ote: The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equipment not supplied by Sartorius and must check and, if necessary, correct these modifications and connections. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the Standards listed above for defined immunity to interference).
  • Page 30 All rights reserved. N o part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below.

Table of Contents