Configuration Lock Time:setinhibit、Getinhibit - DFRobot SEN0521 User Manual

5.8g microwave radar module
Table of Contents

Advertisement

existent if it does not
exist for 15 seconds.
Configuration Lock Time:setInhibit、getInhibit
4.1.4
Describe:
 The default lock time for configuration is 1 second, which activates the lock detection function.
 After the module detects the target, the default lock detection function lasts for 1 second, while
the OUT pin outputs a control signal. After the duration of the control signal ends, the default
lock detection function will last for another 1 second before allowing a target to be detected
again.
 The lock time is primarily used to address the issue of controlling high-power appliances (such as
relays, motors, fans, lighting, etc.) that may produce power fluctuations or radiation when the
control signal changes on the OUT pin, which could interfere with the radar module. During the lock
time, targets are not detected, thereby avoiding sudden interference.
Command for configuring parameters:
Send command:setInhibit par1
Command for reading configuration parameters:
Send command:getInhibit
Command response:Response par1
Parameter item:
par1
Command execution result:
Done
Error
Example:
Set the blocking time to
0.5 seconds, i.e., do not
detect the target for 0.5
seconds.
Set the blocking time to 3
seconds, i.e., do not
detect the target for 3
seconds.
Block time, in seconds:
Value range: 0.1~255; default 1.
Command executed successfully.
Command execution failed.
setInhibit 0.5
leapMMW:/>
setInhibit 3
leapMMW:/>
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEN0521 and is the answer not in the manual?

Questions and answers