6. Connect the battery cable to the battery cable interposer card.
7. Align the ServeRAID SAS controller with the connector and the bracket on the
storage-riser-card assembly and press the controller into place.
Attention:
When you move the storage-riser-card assembly, do not allow it
to touch any components or structures inside the 3U chassis.
8. Align the storage-riser-card assembly with the guide pins and the slot in the
system-board tray cover.
9. Press the assembly into place on the bracket.
10. Reconnect the signal cables to the ServeRAID SAS controller.
11. Align the top-cover assembly with the rear of the 3U chassis; then, slide it
forward until it clicks into place.
12. Reinstall the 3U chassis in the iDataPlex rack (see "Reinstalling a 3U chassis
in an iDataPlex rack" on page 50).
13. Install the hard disk drives (see "Installing a hard disk drive" on page 36).
14. Reconnect the cables on the front of the system-board tray.
15. Turn on the system-board tray (see "Turning on the system-board tray" on
page 21).
16. Make sure that the power-on LED on the system-board tray operator panel is
lit continuously, indicating that the system-board tray is receiving power and is
turned on.
Chapter 3. Installing optional devices