Download Print this page
Berker 9450 01 00 Operation And Assembly Instructions

Berker 9450 01 00 Operation And Assembly Instructions

Radio switch actuator rmd

Advertisement

Quick Links

radio bus
Radio switch actuator RMD
Radio switch actuator RMD
Order-No. : 9450 01 00
Operation- and
Assembly Instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Switch actuator
(2) Programming button
(3) LED
(4) Connection terminal for bus cable
3 Function
Intended use
-
Radio-controlled switching of incandescent lamps, fluorescent lamps, HV halogen lamps
and Tronic or inductive transformers with halogen lamps
-
Operation with suitable radio transmitters in combination with RMD radio receivers or via
extension units
82549911
97-09567-000
Figure 1
Seite 1/4
17.12.2010

Advertisement

loading
Need help?

Need help?

Do you have a question about the 9450 01 00 and is the answer not in the manual?

Questions and answers

Summary of Contents for Berker 9450 01 00

  • Page 1 Radio switch actuator RMD Radio switch actuator RMD Order-No. : 9450 01 00 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
  • Page 2 radio bus Radio switch actuator RMD Suitable for mixed operation up to the specified output (Technical data) Installation in distribution boxes on DIN rail according to DIN EN 60715 i It is not possible to teach a combination of presence detector and motion detector. Product characteristics Connection of installation buttons as extensions possible Light scene operation possible...
  • Page 3 radio bus Radio switch actuator RMD i The polarity of the bus cables (7) must not be reversed. i For the bus cable, use a shielded cable with twisted conductors and a conductor diameter of 0.8 mm that is designed for a test voltage of 2.5 kV AC. Examples of permissible bus cables are YCM 2×2×0.8 or J-Y(St)Y 2×2×0.8.
  • Page 4 Our products are under guarantee within the scope of the statutory provisions. If you have a warranty claim, please contact the point of sale or ship the device postage free with a description of the fault to the appropriate regional representative. Berker GmbH & Co. KG Klagebach 38 58579 Schalksmühle/Germany...