9.5.3 Main zone
EPRA14~18DAV3+W1 + ETVZ16S18+23DA6V+9W
Daikin Altherma 3 H HT F
4P587503-1A – 2020.01
#
Code
[1.6]
[2-0A]
[1.7]
[2-09]
Overview
The following items are listed in the submenu:
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
Setpoint screen
Control the leaving water temperature for the main zone via setpoint screen [2]
Main zone.
See
"9.3.5 Setpoint
screen" [
Schedule
Indicate if the temperature of the leaving water is defined according to a schedule
or not.
Influence of the LWT setpoint mode [2.4] is as follows:
▪
In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving
water temperatures, either preset or custom.
▪
In Weather dependent LWT setpoint mode, the scheduled actions consist of
desired shift actions, either preset or custom.
Room sensor offset (Human Comfort
Interface (BRC1HHDA used as room thermostat)):
Offset on the actual room temperature measured
by the Human Comfort Interface.
▪
–5°C~5°C, step 0.5°C
Room sensor offset (external room sensor
option): Only applicable if the external room
sensor option is installed and configured.
▪
–5°C~5°C, step 0.5°C
[2] Main zone
Setpoint screen
[2.1] Schedule
[2.2] Heating schedule
[2.3] Cooling schedule
[2.4] Setpoint mode
[2.5] Heating WD curve
[2.6] Cooling WD curve
[2.7] Emitter type
[2.8] Setpoint range
[2.9] Control
[2.A] Thermostat type
[2.B] Delta T
[2.C] Modulation
[2.D] Shut off valve
[2.E] WD curve type
4
116].
9
Configuration
|
Description
Installer reference guide