To Connect The Main Power Supply - Daikin EPRA18DAW1 Installer's Reference Manual

Hide thumbs Also See for EPRA18DAW1:
Table of Contents

Advertisement

8
|
Electrical installation

8.3.1 To connect the main power supply

Installer reference guide
92
Item
Power consumption
control settings
1 Open the following (see
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection cable
(= main power supply)
A
B
A
B
X1M
a
Interconnection cable (=main power supply)
On the user interface, make sure to set:
[9.9.1]=1 (Power
Continuous)
[9.9.2]=1 (Type = kW)
"6.2.5 To open the indoor
Wires: (3+GND)×1.5 mm²
1 2 3
a
1 2 3
X2M
X11YB
X11YA
X11Y
X1A
Requirement
consumption
control =
4
unit" [
 50]):
a
EPRA14~18DAV3+W1 + ETVZ16S18+23DA6V+9W
Daikin Altherma 3 H HT F
4P587503-1A – 2020.01