Field settings table
Breadcrumb
Field code
Setting name
└─ Heating WD curve
3.5
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
3.5
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
3.5
[0-02]
High ambient temp. for LWT add zone heating WD curve.
3.5
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
└─ Cooling WD curve
3.6
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
3.6
[0-05]
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
3.6
[0-06]
High ambient temp. for LWT add zone cooling WD curve.
3.6
[0-07]
Low ambient temp. for LWT add zone cooling WD curve.
Additional zone
3.7
[2-0D]
Emitter type
└─ Setpoint range
3.8.1
[9-05]
Heating minimum
3.8.2
[9-06]
Heating maximum
3.8.3
[9-07]
Cooling minimum
3.8.4
[9-08]
Cooling maximum
Additional zone
3.A
[C-06]
Thermostat type
└─ Delta T
3.B.1
[1-0C]
Delta T heating
3.B.2
[1-0E]
Delta T cooling
Additional zone
3.C
WD curve type
Space heating / cooling
└─ Operation range
4.3.1
[4-02]
Space heating OFF temp
4.3.2
[F-01]
Space cooling OFF temp
Space heating / cooling
4.4
[7-02]
Number of zones
4.5
[F-0D]
Pump operation mode
4.6
[E-02]
Unit type
└─ Pump limitation
4.8.1
[9-0E]
Main zone
4.8.2
[9-0D]
Additional zone
Space heating / cooling
4.9
[F-00]
Pump outside range
4.A
[D-03]
Increase around 0°C
4.B
[9-04]
Overshoot
4.C
[2-06]
Antifrost
Tank
5.2
[6-0A]
Comfort setpoint
(*1) *6V_
(*2) *9W_
(*3) + EKHVCONV2
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/W
R/W
R/W (*3)
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Only applicable in Swedish language.
Range, step
Default value
[9-05]~min(45,[9-06])°C, step: 1°C
[2-0C]=0
25°C
[2-0C]=1
35°C
[2-0C]=2
35°C
[9-05]~[9-06]°C, step: 1°C
[2-0C]=0
35°C
[2-0C]=1
45°C
[2-0C]=2
65°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-15°C
[9-07]~[9-08]°C, step: 1°C
[2-0C]=0
18°C(*3)
[2-0C]=1
7°C(*3)
[2-0C]=2
18°C(*3)
[9-07]~[9-08]°C, step: 1°C
22°C(*3)
25~43°C, step: 1°C
35°C(*3)
10~25°C, step: 1°C
20°C(*3)
0: Underfloor heating
1: Fancoil unit
2: Radiator
15~37°C, step: 1°C
25°C
[2-0D]=2:
37~70, step: 1°C
70°C
[2-0D]≠2:
37~55, step: 1°C
55°C
5~18°C, step: 1°C
7°C(*3)
18~22°C, step: 1°C
22°C(*3)
0: -
1: 1 contact
2: 2 contacts
3~10°C, step: 1°C
10°C
3~10°C, step: 1°C
5°C(*3)
0: 2-points
1: Slope-Offset
14~35°C, step: 1°C
35°C
10~35°C, step: 1°C
20°C(*3)
0: 1 LWT zone
1: 2 LWT zones
0: Continuous
1: Sample
2: Request
0: Reversible (*3)
1: Heating only
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
0: Restricted
1: Allowed
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
1~4°C, step: 1°C
1°C
0: Disabled
1: Enabled
30~[6-0E]°C, step: 1°C
60°C
3/11
Installer setting at variance with
default value
Date
Value
4P586462-1 - 2019.07