Table 1-2 System Status Leds - SMC Networks SMC6248M Installation Manual

Tigerstack 10/100 48-port 10/100mbps stackable managed switch
Hide thumbs Also See for SMC6248M:
Table of Contents

Advertisement

LED
Condition
PWR
On Green
On Amber
Off
Diag
Flashing Green
On Green
On Amber
RPU
On Green
On Amber
Off
Stack Master
Flashing Amber
On Green
On Amber
Flashing Green
Off
Table 1-2
System Status LEDs
Status
The unit's internal power supply is operating
normally.
The unit's internal power supply has failed.
The unit has no power connected or the
power supply has failed.
The system diagnostic test is in progress.
The system diagnostic test has completed
successfully.
The system diagnostic test has detected a fault.
A redundant power unit is attached and is in
backup or active mode.
There is a fault in the redundant power unit.
There is no redundant power unit currently
attached.
An initial on state during which the stack
configuration is detected.
This switch is acting as the Master unit in the
stack.
This switch is acting as a Slave unit in the
stack.
When the user enters the light unit command
in the CLI, the unit ID of each switch in the
stack will be displayed by the port LEDs 1 to
8.
System in standalone mode.