SIIG SC-SAE312-S3 Quick Installation Manual

Esata ii pcie pro raid

Advertisement

Quick Links

Introducing the eSATA II PCIe Pro RAID
The eSATA II PCIe Pro RAID is an ultra high-speed two
channel Serial ATA Generation II RAID controller for use
in PCI Express enabled systems.
Features and Benefits
Compliant with PCI Express Base Specification 1.0a
Compliant with Serial ATA 1.0 specifications with
support for full complement of SATA II optional
features
PCI Express 1-lane (x1) SATA II adapter works with
PCI Express slots with different lane width
Installs in any available PCI Express slot and
supports data transfer rates up to 3.0Gbps (300MBps)
Supports Native Command Queuing (NCQ),
Non-zero offsets NCQ, and Out-of-order data
delivery NCQ
Independent command fetch, scatter/gather, and
command execution
Supports RAID 0 (striping) and RAID 1 (mirroring)
for speed and data protection respectively
System Requirements
PCI Express enabled system with one available PCI
Express slot
Windows 2000/XP (32-/64-bit)/Server 2003
(32-/64-bit)/Vista (32-/64-bit)
2 External SATA drives
04-0396B
eSATA II PCIe Pro RAID

Quick Installation Guide

1

Advertisement

Table of Contents
loading

Summary of Contents for SIIG SC-SAE312-S3

  • Page 1: Quick Installation Guide

    eSATA II PCIe Pro RAID Quick Installation Guide Introducing the eSATA II PCIe Pro RAID The eSATA II PCIe Pro RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems. Features and Benefits •...
  • Page 2: Hardware Installation

    Package Contents • eSATA II PCIe Pro RAID board • Driver software CD • Quick Installation Guide Layout External connectors HDD Activity Figure 1. eSATA II PCIe Pro RAID layout Hardware Installation General instructions for installing the card are provided below.
  • Page 3 Turn OFF the power to your computer and any other connected peripheral device. Unplug the power cord from the back of the computer. Remove your computer cover. Remove the slot bracket from an available PCI Express slot. To install the card, carefully align the card's bus connector with the selected PCI Express slot on the motherboard.
  • Page 4: Table Of Contents

    RAID Arrays RAID Arrays are setup in the eSATA II PCIe Pro RAID BIOS. RAID 0 (Striping) ... page 4-5 RAID 1 (Mirror) ... page 5-6 Single Drive Setup (Contiguous) ... page 7 JBOD Drive Setup (Concatenated) ... page 7-8 Rebuilding a Failed Mirror Set ...
  • Page 5: Raid 1 (Mirror)

    When asked Are You Sure (Y/N)?, press Y to accept. Press Ctrl+E to exit the BIOS. When asked Are you sure to exit (Y/N)?, press Y to exit and reboot. Continue with Fdisk and Format steps as if you were installing a conventional hard drive. Manual Configuration As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS.
  • Page 6 At the next screen select Create RAID Set, then press Enter. At the next screen select RAID1, then press Enter. Select Auto configuration, then press Enter. Input the RAID size, then press Enter. When asked Are You Sure (Y/N)?, press Y to accept. Press Ctrl+E to exit the BIOS.
  • Page 7: Single Drive Setup (Contiguous)

    Single Drive Setup Setting up your hard drive to operate as a single drive may destroy all existing data on your hard drive, therefore, back up any data on your hard drive before connecting it to the raid controller or use a blank or new hard drive. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS.
  • Page 8: Rebuilding A Failed Mirror Set

    At the next screen select Create RAID Set, then press Enter. Select Concatenation, then press Enter. Select 2, then press Enter. Select one hard disk drive, then press Enter. Select the second hard disk drive, then press Enter. When asked Are You Sure (Y/N)?, press Y to accept. Note: In the RAID BIOS screen, under Logical Drive, SiI Concatenation and the size of the logical drive will appear.
  • Page 9: Deleting Raid Arrays

    Input the RAID size, press Enter. When asked Are You Sure (Y/N)?, press Y to confirm. Select Rebuild Raid 1 Set, press Enter. When asked Are you sure (Y/N)?, press Y confirm. The mirror will begin rebuilding. Do not interfere with the process.
  • Page 10: Resolving Conflicts

    Resolving Conflicts When a RAID set is created, the metadata written to the disk includes drive connection information. If, after a disk failure, the replacement disk was previously part of a RAID set (or used in another system), it may have conflicting metadata.
  • Page 11: Driver Installation

    Driver Installation This section provides information on how to install the eSATA II PCIe Pro RAID drivers. Windows 2000 For A New Installation A new installation of Windows 2000 requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the 32bit folder, found on the driver CD, onto a blank floppy disk then follow the directions below.
  • Page 12 Insert the driver CD, check CD-ROM drives, uncheck the other boxes, click Next, click Next again, then click Finish. Repeat steps 2-4. Restart Windows to complete the installation. When Windows resumes, go to SATARaid5 GUI on page 16 and install the RAID utility. 32-bit Windows XP/Server 2003 For A New Installation A new installation requires a floppy disk for the driver...
  • Page 13 For An Existing Installation Setup the RAID array prior to driver installation and boot up to Windows. At the Found New Hardware Wizard: XP (w/SP1 or earlier)/Server 2003: continue to step #3. XP (w/SP2 or later)/Server 2003 (w/ SP1 or later): select No, not at this time, then click Next.
  • Page 14 Press Enter to finish driver installation, then follow the on-screen instructions to complete Windows installation. When Windows installation completes, go to SATARaid5 GUI on page 16 and install the RAID utility. For An Existing Installation Setup the RAID array prior to driver installation and boot up to Windows.
  • Page 15 Windows Vista ™ For A New Installation Setup the RAID array prior to Windows installation. Follow Windows installation procedure. At Where do you want to install Windows?, click Load Drivers. Insert the driver CD, click Browse. Double click your CD-ROM drive: For 32-bit Windows Vista: select 32bit, then click OK.
  • Page 16 SATARaid5 GUI The SATARaid5 GUI provides the user an easy way to monitor your RAID set. SATARaid5 GUI Installation Important: Windows 2000 SP4 or later is required for installation. Insert the driver installation CD. At the Windows desktop click Start: For 2000: Click Run, type D:\gui\setup2000.msi, then click OK.
  • Page 17 RAID Groups window RAID Groups window This window identifies SATA host adapters and configured RAID groups. Selecting each RAID group in the RAID Groups window, members consisting of the RAID group will be highlighted in the Device Configuration window. Right clicking on each node in the RAID Groups window, a popup menu will be displayed to let the user select an action to be performed for the selected controller or RAID group.
  • Page 18 SATARAID 5 Configuration Menu SATARAID5 configuration menu includes customization of the settings for Log File, Popup and Advanced Options. By clicking on File, then Configuration, the user may customize the settings for Log File, Popup and Advanced Options tabs. Log File The log file is used to store event information received from all the RAID drivers.
  • Page 19 Popup The popup window is a visual notification that an event has occurred. The popup window can be disabled or set to popup for only certain event levels. The different levels are: Informational - The popup window will be displayed for the following events: - Informational - Warnings...
  • Page 20 Advanced RAID Features: When this feature is selected and the user selects to create RAID group, if the RAID group to be created is fault tolerant group (RAID1), the user will be able to select Improper Shutdown Policy in the Create RAID Group dialog box. The Advanced RAID Features are not supported for Legacy RAID groups.
  • Page 21 Device Summary This command displays the Segment Summary window to show all physical devices' segments. RAID Group Menu Command Create RAID Group This command displays a dialog box to let user create a RAID group, the user needs to specify the following parameters: RAID Group Label: Provides a name for the RAID group.
  • Page 22 RAID Group Summary This command displays a dialog box to show all RAID groups' group ID, configuration and status. The RAID Group Summary window has it's own menu bar. All options available via the menu bar are shown below. Sorting: This command displays a dialog box to let the user choose up to 3 items to sort RAID group items in the RAID Group Summary window.
  • Page 23 Resume: This command allows the user to resume the suspended task items. Cancel: This command allows the user to cancel the selected task items. Delete: This command displays a dialog box to let the user delete the selected task items. Event Log This command displays the Event Log window.
  • Page 24 Capacity: Select from a list of RAID group sizes. Chunk Size: Select one value from the available list. Rebuild Priority: Select from the available list. RAID 0 and virtual disk do not require this. 10 is the highest level of rebuild priority which means that rebuild times will be faster but will take more CPU resources to rebuild.
  • Page 25 Blank Page...
  • Page 26 Blank Page...
  • Page 27: Technical Support And Warranty

    Step 1: Submit your RMA request. Go to www.siig.com, click Support, then RMA to submit a request to SIIG RMA. If the product is determined to be defective, an RMA number will be issued. Step 2: After obtaining an RMA number, ship the product.
  • Page 28 6078 Stewart Avenue Fremont, CA 94538-3152, USA eSATA II PCIe Pro RAID is a trademark of SIIG, Inc. SIIG and the SIIG logo are registered trademarks of SIIG, Inc. Microsoft, Windows and Windows Vista are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

Table of Contents