Page 1
All manuals and user guides at all-guides.com 2 1 . 0 5 – 5 1 6 7 5 5 7 _ 0 2 T r a n s l a t i o n f r o m o r i g i n a l NRK 0150-0700 I n s t a l l a t i o n m a n u a l 60Hz...
Page 2
All manuals and user guides at all-guides.com...
Page 3
All manuals and user guides at all-guides.com Dear Customer, Thank you for wanting to learn about a product Aermec. This product is the result of many years of experience and in-depth engineering research, and it is built using top quality materials and advanced technologies.
Page 4
All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, Aermec shall not be held liable for any errors or omissions.
All manuals and user guides at all-guides.com TABLE OF CONTENTS General warnings .................................6 Reception ..................................8 Storage ..................................10 Dimensions - lifting points - antivibrant position mounts ................. 11 Position of hydraulic connections ........................15 Weight distribution..............................17 Minimum technical spaces ............................ 20 Hydraulic connections .............................
An accidental release of refrigerant may cause risk of suffocation currently in force. Assess the procedures Aermec requires and due to a lack of oxygen: install the machine in a well ventilated...
Page 7
All manuals and user guides at all-guides.com Install the unit at a distance enough from the exhaust wells, to ensure The machine and the pipes have very hot and very cold surfaces that that the possible loss of gas may reach and pollute the aquifer lead to risk of burns Keep all lubricants in properly marked containers do not keep Before opening a machine panel, ascertain whether it is or not firmly...
- Check that the equipment supplied corresponds to the order and Packaging label delivery note Product identification The Aermec products can be identified by the packaging label bearing the identification data of the product and by the technical plate bearing the performance and technical data of your unit. Technical plate...
Page 9
Targhetta tecnica All manuals and user guides at all-guides.com HANDLING (0150÷0700) DISEGNO SPECIFICO DEL MODELLO- SOLLEVAMENTO UNITÀ CON CINGHIE, CORDE O FUNI ATTENTION The unit comes xed on a pallet. Use forklifts for handling LIFTING (0150) LIFTING (0300÷0700) ATTENTION The unit comes xed on a pallet. Use forklifts for handling ATTENTION: Diameter of holes Ø...
ATTENTION: The use of anti-vibration supports MUST be combined with the installation in the unit water piping of exible couplings. The anti- vibration supports must be xed to the unit BEFORE it is earthed. AERMEC is not responsible for the choice of capacity of the anti-vibration supports.
All manuals and user guides at all-guides.com DIMENSIONS - LIFTING POINTS - ANTIVIBRANT POSITION MOUNTS NRK 0150 A 3.0 in 62.9 in 3.0 in 29.6 in 69.1 in 5.5 in 68.8 in 29.7 in Size 0150 Dimensions + package Height 62,3 Width 34,3...
Page 12
All manuals and user guides at all-guides.com NRK 0300 A 7.9 in 110.3 in 7.9 in 23.6 in 25.4 in 126.1 in 43.3 in Size 0300 Dimensions + package Height 70,1 Width 45,7 Depth 128,4 21.05 – 5167557_02...
Page 13
All manuals and user guides at all-guides.com NRK 0330-0350-0550 A 7.9 in 51.5 in 51.5 in 20.6 in 0.8 in 0.8 in 23.2 in 28.7 in 131.5 in 43.3 in Size 0330 0350 0550 Dimensions + package Height 79,9 79,9 79,9 Width 46,1...
Page 14
All manuals and user guides at all-guides.com NRK 0600-0650-0700 A 0.8 in 0.8 in 8.1 in 85.0 in 56.7 in 20.7 in 170.6 in 43.3 in Size 0600 0650 0700 Dimensions + package Height 79,4 79,4 79,4 Width 46,1 46,1 46,1 Depth 172,8...
All manuals and user guides at all-guides.com POSITION OF HYDRAULIC CONNECTIONS COMPONENTS SUPPLIED AS STANDARD (FOR SIZES 0300-0330-0350-0550-0600-0650-0700 ) 0.6 in 0.6 in 3.9 in Grooved joints EU Grooved joint USA Grooved nipple USA Reduction/adapter EU-USA NRK 0150 A (00-01-03-P1-P3) NRK 0300 A (00) 29.6 in IN Water 1"1/4...
Page 16
All manuals and user guides at all-guides.com NRK 0330-0350-0550-0600-0650-0700 A (00) 9.7 in 43.3 in NRK 0330-0350-0550-0600-0650-0700 A (01-04) NRK 0330-0350-0550-0600-0650-0700 A (P1-P4) 9.7 in 9.7 in 21.7 in 43.3 in 43.3 in 21.05 – 5167557_02...
All manuals and user guides at all-guides.com WEIGHT DISTRIBUTION NRK 0150 NRK 0300 top view top view NRK 0330÷0550 NRK 0600÷0700 top view top view 21.05 – 5167557_02...
Page 18
All manuals and user guides at all-guides.com Centre of mass Empty weight Model Hydronic kit (lbs) Xg (in) Yg (in) 13.7 38.5 0150 P1-P3 13.8 36.7 01-03 13.9 36.8 1,729 21.9 46.8 P2-P4 1,892 22.3 49.9 0300 P1-P3 1,844 22.3 48.8 02-04 2,146...
Page 19
All manuals and user guides at all-guides.com Centre of mass Operation Model Hydronic kit weight (lbs) Xg (in) Yg (in) 13.7 38.5 VT 15 0150 P1-P3 13.8 36.7 VT 15 01-03 1,212 13.9 36.8 VT 15 1,742 21.9 46.7 VT17 P2-P4 1,927 22.4...
The water circulation pump must aermec.com concentrated to ensure proper protection and prevent ice forming However, always refer to the glycol supplier documentation to check its preferably be installed upstream so that the evaporator/condenser is at minimum temperature provided for a given installation.
All manuals and user guides at all-guides.com MAIN HYDRAULIC CIRCUITS NRK 0150 (00) Components as standard Pump Plate heat exchanger Air drain valve Water temperature sensors (IN/OUT) Pressure gauge Pressure relief valve Expansion vessel Water filter Storage tank Air drain valve Antifreeze electric heater Flow switch Drain valve...
Page 23
All manuals and user guides at all-guides.com NRK 0150 (P1-P3) Components as standard Components not provided and responsibility of the installer Plate heat exchanger Anti-vibration joints Water temperature sensors (IN/OUT) Flow shut-off valves Water filter Air drain valve Pump Pressure gauge Air drain valve Storage tank Expansion vessel...
Page 24
All manuals and user guides at all-guides.com NRK 0150 (01-03) Components as standard Antifreeze electric heater Plate heat exchanger Drain valve Water temperature sensors (IN/OUT) Flow switch Water filter Components not provided and responsibility of the installer Pump Anti-vibration joints Pressure relief valve Flow shut-off valves Air drain valve...
Page 25
All manuals and user guides at all-guides.com NRK 0300-0700 (00) Components as standard Pump Plate heat exchanger Pressure gauge Water temperature sensors (IN/OUT) Flow shut-off valves Flow switch Expansion vessel Air drain valve Air drain valve Water filter Safety valve Drain valve Loading unit Components not provided and responsibility of the installer...
Page 26
All manuals and user guides at all-guides.com NRK 0300-0700 (P1-P2-P3-P4) P2-P4 Components as standard Components not provided and responsibility of the installer Plate heat exchanger Anti-vibration joints Water temperature sensors (IN/OUT) Drain valve Flow switch Pressure gauge Expansion vessel Flow shut-off valves Air drain valve Expansion vessel Water filter...
Page 27
All manuals and user guides at all-guides.com NRK 0300-0700 (01-02-03-04) 02-04 Components as standard Flow shut-off valves Plate heat exchanger Expansion vessel Water temperature sensors (IN/OUT) Safety valve Flow switch Storage tank Air drain valve Antifreeze electric heater Components not provided and responsibility of the installer Water filter Pump (01-03: Storage tank and pump / 02-04: Storage tank with pump + stand- Anti-vibration joints...
All manuals and user guides at all-guides.com ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS ATTENTION The units are completely wired at the factory and only require connection to the electric power supply mains, downstream from a unit switch, • All the electrical operations must be carried out by personnel in according to that envisioned by the Standards in force on this subject in the possession of the necessary quali cations by law, suitably trained and country of installation.
All manuals and user guides at all-guides.com ELECTRIC POWER CONNECTION TO THE ELECTRICAL MAINS ELECTRIC POWER CONNECTION TO THE ELECTRICAL MAINS • Open the external covering panels (if present) • For the functional connection of the unit, take the power supply •...
All manuals and user guides at all-guides.com COMMISSIONING - WARNINGS COMMISSIONING - WARNINGS Please note that, on request by the Aermec customer or the legitimate COMMISSIONING owner of the machine, the units in this series can be started up by...
All manuals and user guides at all-guides.com MAINTENANCE MAINTENANCE ATTENTION place before restarting the unit; Any cleaning, inspection, control, routine and extraordinary mainte- It is not permitted to walk or place other bodies on the machine; nance must be performed by experienced, authorised personnel and Fans, motors and belt drives may be in motion, always wait for them quali ed to perform the above tasks.
Page 32
Always and only use original spare parts purchased directly from Aer- if these devices intervene, the refrigerant gas is released at high mec or from official dealers. Contact Aermec should it be necessary temperature and speed; to move the unit one year after its positioning on-site or it must be The machine and the pipes have very hot or very cold surfaces that lead to risk of burns by contact;...
Page 33
All manuals and user guides at all-guides.com With machine off, access its cooling circuit; The high/low pressure switch, where present must be tested with the Connect the necessary instruments, machine “closed”, reading the high pressure circuit pressure on the machine •...
All manuals and user guides at all-guides.com MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS RECOMMENDED PERIODIC MAINTENANCE INTERVENTIONS FREQUENCY DESCRIPTION functioning hours months months months months GENERAL INTERVENTIONS Check of any refrigerant leaks (this must be done respecting the deadlines recommend- •...
Page 35
All manuals and user guides at all-guides.com MAINTENANCE - LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS RECOMMENDED PERIODIC MAINTENANCE INTERVENTIONS TO UNITS WITH CENTRIFUGAL COMPRESSORS FREQUENCY DESCRIPTION 6 months 12 months other GENERAL CHECKS Check that the compressor is not damaged •...
Page 36
All manuals and user guides at all-guides.com DOWNLOAD THE LATEST VERSION: http://www.aermec.com/qrcode.asp?q=15782 A E R M E C S . p . A . V i a R o m a , 9 9 6 - 3 7 0 4 0 B e v i l a c q u a ( V R ) - I t a l y P h o n e .
Need help?
Do you have a question about the NRK 0700 and is the answer not in the manual?
Questions and answers