maintenance mode. After the mode is switched, press the Enter key to select a mode from
the five modes described above. To finish the maintenance mode, press and hold down
the Enter key, or leave for more than 60 seconds with no panel operation.
Figure 13 Maintenance mode diagram
Figure 13 Commissioning mode diagram
Display Sleep Mode
Display Sleep Mode
Any Key
No Operation
No Operation
for 60sec.
Any Key
for 60sec
Clock Display Mode
Clock Display Mode
Enter
Enter
Enter
Enter
No Operation
No Operation
for 60sec.
for 60sec
Clock Setting Mode
Clock Setting Mode
Heat Setting
Enter into Commissioning Mode
Enter into Commissioning Mode
First option is the Heat Setting – Press Enter one more time to access this
First option is the Heat Setting – Press Enter one more time to access this
Use UP/DOWN arrow keys to toggle between Heat On and Heat Off
Use UP/DOWN arrow keys to toggle between Heat Nor and Heat Off
Press Enter to confirm choice
Press Enter to confirm choice
To bypass the Heat Setting simply press the UP key to access the next parameter in the
Commissioning menu
Temperature Setting
Enter into Commissioning Mode
First option is the Heat Setting –
Press the UP Key to access Temperature Setting then Press Enter to access
Use UP/DOWN arrow keys to toggle between the various Temperature Settings
Press Enter to confirm choice
Settings available 130, 140, 150, 160, 165, 175°F
To bypass the Temperature setting simply press the UP key to access the next parameter
in the Commissioning menu
Hold down " UP " and
" DOWN " together
Hold down "UP" and
"DOWN" together
Press and
hold down Enter
Hold Enter
or
or
No Operation
or
No Operation
or
for 60sec.
for 60sec
Sanden Heat Pump – Installation Manual
Sanden Heat Pump – Installation Manual
SANCO
Heat Pump – Installation Manual
2
" DOWN " is reverse
"DOWN" is reverse
Heat Setting Mode
Heat Setting Mode [H_SE]
UP
Outlet water Temp Setting Mode
Block out Time Setting Mode [bo ]
UP
Block out Time Setting Mode
Error History Display Mode [Err ]
UP
Error History Display Mode
Parameter Display Mode [d_no]
UP
Air Bleeding Mode [Air ]
Parameter Display Mode
Air Removing Mode [Air ]
Page 17 of 32
Page 20 of 40
Page 22 of 44
Enter
Enter
Enter
Enter
Enter
UP
UP
Enter
Enter
Enter
Enter
Enter