  • Page 1 SAVE VTC 300 Installation instructions Document in original language | 333569 · v1.1...
  • Page 2 This also applies to products already ordered, as long as it does not affect the previously agreed specifications. Systemair is not liable or bound by warranty if these instructions are not adhered to during installation or service. 333569 | v1.1...
  • Page 3: Table Of Contents

    Contents Overview ............1 General Description ........1 Warranty ..........1 Type label..........1 Important Safety Information ......1 Intended Use.........1 Admonitions .........2 Technical Data ..........2 Dimensions and Weight ......3 Connections Left and Right models.....4 Installation recommendation regarding condensation ........4 3.3.1 Condensation inside of the unit .........4 3.3.2 Condensation outside of the...
  • Page 5: Overview

    For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance with the data sheets. Further prerequisites are a completed maintenance plan with no gaps and a commissioning re- port. Systemair will require these in the case of a warranty claim. Type label Before calling your service representative, make a note of the specification and production number from the type label, which can be found next to the external connections and inside of the unit.
  • Page 6: Admonitions

    | Technical Data • The system should operate continuously, and only be stopped for maintenance/service. • Do not connect tumble dryers to the ventilation system. • Make sure that filters are mounted before starting the unit. Admonitions Danger • Make sure that the mains supply to the unit is disconnected before performing any maintenance or electrical work! •...
  • Page 7: Dimensions And Weight

    Technical Data | Dimensions and Weight Fig. 2 Dimensions of right hand unit * Inspection hatch. ** Drainage. The unit weight is 72 kg. 333569 | v1.1...
  • Page 8: Connections Left And Right Models

    | Technical Data Connections Left and Right models Fig. 3 Duct connections Position Description Right hand model (Supply air connection is situated on the right hand side of the unit viewed from the front) Left hand model (Supply air connection panel is situated on the left hand side of the unit viewed from the front) Description Description...
  • Page 9: Condensation Outside Of The Unit

    Transport and storage The SAVE VTC 300 should be stored and transported in such a way that it is protected against physical damage. It should be covered so dust, rain and snow cannot enter and damage the unit and its components.
  • Page 10: Location And Space Requirements

    Access to Power supply The SAVE VTC 300 is supplied with approximately 1 – 1,5 m cable and plug for 230V, single phase earthed connection. Make sure a power outlet is reachable by the plug.
  • Page 11 Installation | C — concrete/bricks, W — wood block, G — gypsum, M — mineral wool X* — adaptable height according to needs. Make sure the mounting bracket is completely level. 333569 | v1.1...
  • Page 12: Ventilation Duct Connection And Insulation

    Please follow instructions included with the accessory or consult “Service and Accessories Installation” manual which can be found in our online catalogue. Electrical connections Main circuit board layout The SAVE VTC 300 is equipped with built-in regulation and internal wiring. 333569 | v1.1...
  • Page 13: External Connections (Connection Board)

    Electrical connections | Fig. 4 Main circuit board connections Position Description Connection to the external connection box Terminals for a heater Terminals for a TRIAC Terminals for the mains power supply Terminals for power supply of extract air fan Terminals for power supply of supply air fan Terminals for internal relative humidity/temperature sensor Analog input 1 —...
  • Page 14: Before Starting The System

    | Before Starting the System Fig. 5 External connection box and board Position Description Connection to the main circuit board Connection for external control panel (HMI) or Internet access module (IAM) Modbus RS485 connection AI6–7 Freely configurable Analog input. None/Input type selection in HMI. DO1–4 Freely configurable digital output.
  • Page 15: Concluding Routines

    Concluding Routines | Note: If the SAVE LIGHT control panel is used, the start-up wizard is skipped and the factory settings are used. Select language, set the time and choose airflow control type. Select revolutions per minute as the type of airflow con- trol only if these values are included with the device.
  • Page 16: Disposal And Recycling

    | Disposal and recycling Disposal and recycling This product is compliant with the European WEEE Directive and related national waste legislation. When disposing the unit, follow your local rules and regulations. This product packing materials are recyclable and can be reused. Do not dispose in household waste.
  • Page 17: Eu Declaration Of Conformity

    Degrees of protection provided by enclosures (IP Code). The manufacturer hereby confirms that EN 62233 SAVE VTC 300 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard comply with all applicable requirements in the following to human exposure.