COMMAND STRUCTURE
COMMAND FUNCTION
INPUT TO PRINTER
PRINTER OUTPUT
SPECIAL NOTES
SATO CX400
Print Darkness Range
<ESC>CDaaa,bbb
aaa
=
Example:
Placement:
Default:
To make fine adjustments for best print quality.
<ESC>A
<ESC>CD200,3300
<ESC>Z
There is no printer output as a result of this command.
1. This setting is stored in non-volatile memory and will not change until a
new Print Darkness Range command is received.
2. The current Print Mode can be verified by printing a Test Label.
3. It is recommended that a bar code verifier be used when making
adjustments with this command.
PN 9001106 Rev. A
Section 5. Configuration Commands
Darkness range adjust (0 to 400)
Media adjustment (0 to 6000)
<ESC>CD250,3000
This command should be sent in a separate data
stream.
CD200,3300
Page 5-7