Faults and what to do about them
en
Information on the display panel
Display
è
r
E:18
E:32
:
Other displays
26
Cause/Remedy
Flashes fast + warning signal: The door was opened and the water level is
■
too high. Close the door, continue the programme with A button or select
0 Spin/Drain [ programme.
Flashes slowly: The door lock temperature is too high to open the door. Wait
■
approx. 30 seconds until the door lock temperature cools down.
Flashes (no water supply): Tap turned on? Water inlet filter blocked? Clean
■
the water inlet filter.
If an additional water filter has been installed (depending on the model), check
for contaminants and clean if required ~ separate installation and cleaning
instruction for water filter.
Water hose kinked or blocked?
Lights up (low water pressure): For information only. This will not affect the
■
programme progress. The programme duration is extended.
Drain pump blocked; clean the drain pump. Clean the drainage hose on the siphon.
Alternating display with End when programme is finished: unbalance problem, spin-
ning phase is aborted.
Flashes fast: For information only. Low line voltage is detected. The program
■
duration time might be extended.
Flashes slowly: For information only. Low line voltage is detected during pro-
■
gram running. The program duration time might be extended.
Switch off the appliance, wait for five seconds and then switch it on again. If the dis-
play appears again, call customer services.