Watts AERCO Benchmark OMM-0121 Operation And Maintenance Manual page 104

Natural gas, propane gas and dual fuel fired modulating & condensing boilers
Table of Contents

Advertisement

Benchmark 750-3000 Boiler Operation & Maintenance Manual
APPENDIX F – BENCHMARK 750/1000 PART LIST
Benchmark 750/1000 DBB Gas Train – P/N 22140-2
Item Qty
Part #
Description
1
95026
1.25" NPT 125#: THREADED FLANGE
1
2
92036
VALVE: SSOV 1" NPT
3
1
64048
ACTUATOR: SSOV W/ REGULATOR
4
4
12951-2
BUSHING: CONTROL BOX
6
1
61002-1
LOW PRESSURE SWITCH: 2.6" W.C. FALL N.O.
7
1
99015
DAMPING ORIFICE: SSOV
8
2
9-22
PIPE PLUG: 1/4" NPT: STEEL
13
AERCO International,
Inc. Blauvelt, NY
10913
OMM-0122_D • GF-206 • 5/9/2019
Benchmark 750/1000 DBB Gas Train
22140-2 rev E
Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST
Item
Qty
Part #
Description
1
92006-5
VALVE: BALL 1" NPT
16
1
27086-1
ACTUATOR: SSOV w/o P.O.C. SWITCH
18
1
61002-12
HIGH GAS PRESSURE SWITCH 4.7" W.C.
19
1
GP-122774
VALVE: VENT 3/4" NPT
21
1
99017
SNUBBER: PRESSURE: 1/4"
23
33
3
92077
1/4" NPT MXF BRASS BALL VALVE
36
1
97087-20
TUBE: FLEXIBLE GAS 20" " (50.8 cm) LG
10/15/2015
Sheet 1 of 1
Page 104 of 164