INSTALLATION AND MAINTENANCE INSTRUCTIONS
ELK 15
ELK 15
031179

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELK 15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nibe ELK 15

  • Page 1 MOS GB 0922-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 15 ELK 15 031179...
  • Page 3: Table Of Contents

    Electrical circuit diagram Safety valve Technical specifications Venting Dimensions Draining Component positions Actions in the event of freeze risk List of components Technical specifications For the Installer Dealing with malfunctions General information for the installer Low room temperature ELK 15...
  • Page 4 General General In order to get the ultimate benefit from ELK 15 you should read the "For Home Owners" section in this Installation and Maintenance Instruction. ELK 15 is an immersion heater primarily intended for installation together with heat pump for heating houses or smaller apartment blocks.
  • Page 5: For Home Owners

    Economical A small water volume and a well insulated cassette mean small heat losses. System diagram Additional heat from ELK 15 controlled by the heat pump or the SMO. SÄV ELK 15 ELK 15 LE K ELK 15...
  • Page 6: Operation And Maintenance General

    If a part of the heating system is thought to be frozen, con- tact the installer. If the heating system must be switched off for a long period of time, the water should be drained and the immersion heater blocked. ELK 15...
  • Page 7: For The Installer

    NIBE ground source heat pumps and air/water heat pumps. Electrical installation When the heating demand is greater then heat pump's ca- ELK 15 must be installed via an isolator switch with a minim- pacity, the immersion heater connects automatically as addi- um breaking gap of 3 mm.
  • Page 8: Installation Alternative

    B takes care of the heating. striction of the electrical power for 5 kW within 2 hours FIGHTER 1330 connects ELK 15 in steps when the power from start-up is required. demand exceeds the heat pump’s capacity.
  • Page 9 Electric water heater Auxiliary relay Charge pump Level vessel Particle filter SÄV Safety valve Flow sensor Hot water temperature sensor Outdoor temperature sensor Return temperature sensor VVB/ACK Accumulator with hot water heater Three way valve, VST 11/VST 20 ELK 15...
  • Page 10 For the Installer Installation alternative Electrical connection FIGHTER 1330 Without thermostat ELK 15 FIGHTER 1330 Contactor, 1, -K1 Contactor 2, -K2 J2,2 J1,2 J1,1 With thermostat 10 kW immersion heater step active in emergency mode. FIGHTER 1330 ELK 15 Contactor, 1, -K1...
  • Page 11 2. Select ”Binary” in menu 9.2.12. - "Immersion heater If the heat pump does not manage the heating demand, type". additional heat from ELK 15 is engaged. 3. In menu 8.3.2, check that "Max. electric power permit- When additional heat is engaged, hot water is heated using ted el.-steps"...
  • Page 12: F20Xx With Smo

    The various stages of the immersion heater are con- and follow the corresponding instructions. trolled by relays TS1, TS2 and TS3. Without thermostat 089 638 SMO 10 ELK 15 Contactor, 1, -K1 J2,2 Contactor 2, -K2 J1,2 J1,1 With thermostat...
  • Page 13 Miscellaneous Installation alternative Without thermostat 089 259 SMO 10 ELK 15 Contactor, 1, -K1 J2,2 Contactor 2, -K2 J1,2 J1,1 With thermostat 10 kW electrical step active in emergency mode 089 259 SMO 10 ELK 15 Contactor, 1, -K1 J2,2...
  • Page 14: Miscellaneous

    Miscellaneous Electrical circuit diagram Electrical circuit diagram ELK 15...
  • Page 15: Technical Specifications Dimensions

    Miscellaneous Technical specifications Technical specifications Dimensions Ø6 x4 ELK 15...
  • Page 16: Component Positions

    Overheating protection (-B1) Terminal block (-X9) Contactor, 5.0 kW (-K1) Contactor, 10.0 kW (-K2) Reserve mode thermostat (-B2) Connection, flow line, G 40 Connection, return line, G 40 Cable grommet Venting Sign, serial number Mounting hole 4 x (Ø 6mm) ELK 15...
  • Page 17: Technical Specifications

    15 kW Fuse immersion heater 25 A Enclosure class IP 44 Max permitted pressure in the 0.7 MPa (7 bar) boiler Material immersion heater SIS 2333 EN 1.4301 Material tube SIS 2333 EN 1.4301 Part No. 069 022 ELK 15...
  • Page 18: Dealing With Malfunctions

    Reset by pressing in the button on the overheating protection, Work behind panels secured by screws may only be when the temperature has dropped below 80 °C. carried out by a qualified installation engineer. Circulation pump stopped. ELK 15...
  • Page 20 Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at NIBE Wärmetechnik AG, Winterthurerstrasse 710, CH-8247 Flurlingen Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@nibe.ch www.nibe.ch Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz...