Post-Installation Checks; Testing And Operation; Functional Testing; Appendices - Technibel MAFX96R5I/GRFX96R5I User Manual And Installation Manual

Single-split air conditioner
Table of Contents

Advertisement

• Reinstall the handle.
Leak detection
Check for leaks using a leak detector. If you do not have a leak detector you can use soapy water.

Post-installation checks

Has the unit been installed securely?
Is the thermal insulation of the pipes sufficient?
Does the water drain properly?
Does the supply voltage match the voltage indicated on
the data plate?
Have the piping and electrical wiring been installed
correctly?
Has the unit been properly earthed?
Does the power cable meet requirements?
Are there any obstructions at the air inlet or outlet?
Have the dust and other particles produced during
installation been removed?
Are the gas valve and liquid valve of the connecting tube
fully open?

TESTING AND OPERATION

Functional testing

Connect the power and press the ON/OFF
Press the MODE button to select AUTO, COOL, DRY, FAN and HEAT mode and check the air
conditioner operates normally.
If the ambient temperature is below

APPENDICES

V 11/15
Checks
16°C, the air conditioner will be unable to start cooling.
The unit could fall, move or produce excessive
noise.
Risk of condensation and dripping water.
Risk of condensation and dripping water.
Risk of malfunction or damage to components.
Risk of malfunction or damage to components.
Risk of electric leakage.
Risk of malfunction or damage to components.
The cooling (heating) capacity may be insufficient.
Risk of malfunction or damage to components.
The cooling (heating) capacity may be insufficient.
button on the remote control to start operation.
Possible fault
27

Advertisement

Table of Contents
loading

Table of Contents