Fault
The indoor unit's
Is the indoor temperature and humidity
air outlet
high?
produces a mist
Is the unit operating in automatic mode?
The set
temperature
cannot be
adjusted
Does the desired temperature fall outside
the available temperature range?
Is the voltage too low?
The desired level
Is the filter dirty?
of heating/cooling
Does the set temperature fall within the
cannot be
available temperature range?
achieved
Are there any doors or windows open?
Is there an odour source (e.g. furniture,
The unit is
cigarettes, etc.)?
emitting
unpleasant smells
Are there any sources of interference (e.g.
lightning, wireless devices, etc.)?
The air
conditioner turns
on suddenly
Has heat mode been selected?
The outdoor unit
produces steam
Has the air conditioner recently been
turned on or off?
Sound of running
water
Has the air conditioner recently been
turned on or off?
Creaking/cracking
noises
V 11/15
Check
Solution
Indoor air cools rapidly. Wait for the
indoor temperature and humidity to fall
and the mist to disappear.
The temperature cannot be adjusted in
automatic mode. Change the operating
mode if you want to adjust the
temperature.
The available temperature range is: 16 –
30°C.
Wait for the voltage to return to normal.
Clean the filter.
Adjust the temperature to within the
available range.
Close any doors and windows.
Eliminate the odour source.
Clean the filter.
Disconnect the power supply and then
reconnect it. Turn the unit on again.
Steam production when defrosting in
heat mode is a normal phenomenon.
The noise is produced by the refrigerant
flowing inside the unit (normal
phenomenon).
It is the sound of the friction caused by
the expansion and/or contraction of the
panel or other parts due to temperature
changes.