4. Reposition the terminal block cover and tighten the screws.
5. Close the panel.
N.B.:
• All wiring must be connected as shown on the unit's wiring diagram.
All indoor and outdoor unit cables must be connected by a qualified technician.
If the power cable is not long enough, contact the supplier for a new one. Do not attempt to
extend it yourself.
• For air conditioners equipped with a plug, the plug must be easily accessible upon completion
of installation.
• For air conditioners without a plug, install a circuit breaker on the line.
must be single-pole and the contact gap must be greater than 3mm.
Step eight: bind the pipes
1. Bind together the connecting pipe, the power
cable and the drain pipe with binding tape.
unità
tubo
interna
gas
unitàinterna
cavo di alimentazione interno
ed esterno
tubo gas
fascetta
tubo di scarico
tubo del liquido
2. Reserve a section of the drain pipe and
power cable for installation when binding. When
you have bound up to a certain point, separate
the indoor power cable and then the drain pipe.
Step nine: hang the indoor unit
1. Insert the bound pipes into the wall pipe and route them through the hole in the wall.
2. Hang the indoor unit on the wall-installation plate.
3. Fill the gap between the pipes and the hole in the wall with sealant.
4. Secure the wall pipe.
5. Check that the indoor unit is securely installed and flush against the wall.
interno
tubo a
parete
interno
esterno
tubo a parete
gomma di sigillatura
ganciosuperiore
gancio inferiore del telaio di montaggio a parete
V 11/15
cavo di alimentazione
interno ed esterno
tubo del
liquido
fascetta
tubo di
scarico
indoor unit
indoor and outdoor power cable
gas pipe
binding tape
drain pipe
liquid pipe
esterno
gomma di
sigillatura
tubo di collegamento
cavo di alimentazione interno
tubo di collegamento
tubo di scarico
fascetta
cavo di alimentazione interno
3. Bindthemevenly.
4. The liquid pipe and gas pipe must be bound
separately at the end.
N.B.:
The power cable and signal control cable must
not be rolled or coiled.
The
drain pipe must be bound at the bottom.
gancio superiore
gancio inferiore del telaio
di montaggio a parete
indoors
outdoors
wall pipe
rubber sealant
upper hook
lower hook of wall-installation frame
The circuit breaker
tubo di scarico
fascetta
connecting pipe
drain pipe
binding tape
Indoor powercable