Technibel MAFX96R5I/GRFX96R5I User Manual And Installation Manual page 22

Single-split air conditioner
Table of Contents

Advertisement

Wrap the indoor pipe and the joint of the
connecting pipe with an insulating tube. Then
wrap with tape.
Step six: install the condensate drain pipe
Connect the drain pipe to the outlet pipe of the
indoor unit.
Bind the joint with tape.
N.B.:
Add an insulating tube to the indoor drain pipe to
prevent condensation.
• The plastic wall plugs are not supplied.
Step seven: connect the indoor unit electrical cable
1. Open the panel. Remove the screw that
secures the small panel covering the terminal
board.
2. Insert the indoor and outdoor unit connecting
cable into the rear hole corresponding to the
terminal block. Then pull it out of the front.
3. Remove the cable clip. Connect the power cable to the terminal block according to colour.
Tighten the screw and secure the power cable with the clip.
blu
nero
marrone
giallo-verde
Collegamentounitàesterna
V 11/15
tubo di scarico
tubo d'uscita
nastro
tubo di scarico
tuboisolante
tubo di uscita
tubo di scarico
nastro
pannello
coperchio cablaggio
foro di
passaggio
cavo
cavo di
alimentazione
pannello
vite
coperchiocablaggio
foro di passaggio
cavo
cavo di alimentazione
blue
black
brown
yellow-green
Outdoor unit connection
tubo di scarico
tubo di
uscita
tubo isolante
insulating tube
outlet pipe
drain pipe
tape
vite
panel
screw
wiring cover
cable
through-hole
power cable
22