REAR PANEL FEATURES OVERVIEW

3 4
1. AC Inlet: 100-240 V~ IEC-320 C14 Inlet
2. DC Output Banks 1-12
Each DC Output Bank is comprised of:
• Plug in terminal block connector
» Pin 1: +12VDC
» Pin 2: +5VDC
» Pin 3: DC Common
• USB-A Output Port
» 5VDC, 2.2A max
• Indicator light
Color / State
Status
Off
DC output port is switched off (unenergized)
Blue
DC output port is switched on (energized)
Blue / Flashing
DC output has shut off for overload
All Blue / Flashing
Main DC power supply overload
3. Ethernet / BlueBOLT Port
RJ-45 connector 10/100 Mbps Ethernet. Connect to an active local area network.
• LINK LED: Illuminated green when connected to an active network.
• Activity LED: ashes to indicate active data communication.
4. Reset Button
Located adjacent to the Ethernet port and recessed behind the rear panel.
When the button is pressed and held for 10 seconds, outputs will be turned off immediately then sequenced back on with the default delay values. When