Technical Data - KERN CKE 6K0.02 Operating Instructions Manual

Counting balance
Hide thumbs Also See for CKE 6K0.02:
Table of Contents

Advertisement

1 Technical data

Big housing:
KERN
Item no./ Type
Readability (d)
Weighing range (max)
Taring range (subtractive)
Reproducibility
Linearity
Stabilization time (typical)
Smallest part weight for
piece counting - under lab
conditions*
Smallest part weight for
piece counting - under
normal conditions**
Adjustment points
Recommended
adjustment weight, not
added (class)
Warm-up time
Weighing Units
Humidity of air
Allowable ambient
temperature
Input voltage Appliance
Input voltage Mains
adapter
Batteries (option)
Rechargeable battery
operation (optional)
Auto-Off (battery,
rechargeable battery)
Dimensions housing
Weighing plate, stainless
steel
Net weight (kg)
Interfaces
Underfloor weighing
device
TCKE-A/-B-BA-e-2333
CKE 6K0.02
CKE 8K0.05
TCKE 6K-5-B
TCKE 8K-5-B
0.02 g
6000 g
6000 g
0.04 g
± 0.2 g
± 0.15 g
20 mg
200 mg
500 mg
2/4/6 kg
2/5/8 kg
6 kg (F1)
8 kg (F1)
g, kg, lb, gn, dwt, oz, ozt, pcs, FFA
max. 80% rel. (non-condensing)
110 V – 240 V AC; 50Hz / 60Hz
Operating period 48 h (background illumination OFF)
Operating period 24 h (background illumination ON)
Loading time approx. 8 hrs.
selectable 30 s; 1 / 2 / 5 / 30 / 60 min
350 x 390 x 120 (W x D x H) [mm]
RS-232 (optional), USB-D (optional) via KUP
CKE 16K0.05
TCKE 16K-5-B
0.05 g
0.05 g
8000 g
16000 g
8000 g
16000 g
0.05 g
0.1 g
± 0.25 g
3 s
50 mg
50 mg
500 mg
5/10/15 kg
15 kg (F1)
2 h
- 10 °C ... + 40 °C
6 V, 1 A
4 x 1.5 V AA
340 x 240 (W x D) [mm]
6.5
yes (hook supplied)
CKE 16K0.1
TCKE 16K-4-B
0.1 g
16000 g
16000 g
0.1g
± 0.3 g
100 mg
1 g
5/10/15 kg
15 kg (F1)
4

Hide quick links:

Advertisement

Table of Contents
loading