MAINTENANCE
GENERAL TIPS
Only use filtered/decalcified water in this appliance.
Always ensure that the appliance is sitting on a level surface.
If you intend not using the appliance for longer than a week, remove and empty the sump and water tank.
Once installed, never move this appliance or lay on its back, without draining the water from sump.
CLEANING
WARNING: Always press Switch 'A' to the 'OFF' (0) position
the fire.
We recommend cleaning the following components once every week, particularly in hard water areas:
Sump, Nozzle, Tank cap and seal, Air filter
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or fluff, the soft brush attachment of a vacuum cleaner should occasionally be used.
SUMP
1.
Open the drawer & press switch 'A' to the 'OFF' (0) position
2.
Remove the water tank from its position on top of the sump.
3.
Disconnect the electrical connector to the transducers, located on the right side of the sump.
4.
There are two orange clips holding down the nozzle on the sump; one on the left and one on the right hand side of
the nozzle. On the left side, press in the clip with one hand and with the other lift the nozzle out of the clip. Repeat
this for the right side
5.
Gently lift up the sump
6.
Carefully empty the sump into the sink taking note that the transducer is held in place by a retaining clip.
7.
Put a small amount of washing up liquid into the sump, and using a soft brush, gently clean all surfaces in the sump
and gently clean the transducer including the cone and metal discs located in the top grooved surface.
8.
When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
9.
Clean the nozzle with a soft brush and flush out thoroughly with water.
10.
Reverse the above steps 1 – 6 to reassemble.
TRANSDUCER
The transducer is a consumable item and may need to be replaced through time, depending on its usage. Replacement
transducers can be purchased from your dealer. The transducer is fixed in the sump with a plastic clip. If you need to
replace your transducer:
1.
Follow the steps 1-5 in the CLEANING - Sump section under 'Maintenance' to gain access to the transducer.
2.
Press the clip back and lift the transducer upwards out of its holder.
3.
Place the new transducer into the sump, ensuring the its cable does not sit over the cone.
4.
Reverse the above steps to reassemble the nozzle and sump.
AIR FILTER
1.
Open the drawer to access the air filter at the rear of the module.
2.
Gently slide the air filter upwards out of its plastic holder.
3.
Gently rinse with water in the sink and dry with fabric towel.
4.
Replace the filter making sure that the coarse black filter is facing outwards.
5.
Replace the fuel bed.
NOZZLE INSERTS
Nozzle inserts have been supplied and fitted to the nozzle opening. These inserts are used to alter the profile of the
flame effect. These inserts can be removed if a different flame profile is preferred. In addition to these inserts, inserts for
blocking the flame in certain areas have also been supplied. To fit these inserts, remove the exisitng inserts that have
been supplied and fitted to the product. Break the blocking inserts into the required length. Snap the inserts into the
nozzle opening in the desired location. See
(Fig ).
The nozzle can now be lifted up and placed aside
(Fig ),
taking care to keep it level so as not to spill any water. Sit the sump in the sink.
(Fig )
(Fig )
and disconnect from the power supply before cleaning
(Fig )
(Fig )
for further details.
11
(Fig
).
(Fig ).
Need help?
Do you have a question about the Optimyst 3STEP-RGB-EU and is the answer not in the manual?
Questions and answers