8 Configuration

INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/3+4) as the safety
thermostat. It is only possible for the system to have
EITHER preferential kWh rate power supply OR a safety
thermostat.
7.9.18
To connect the booster heater power
supply
WARNING
The booster heater MUST have a dedicated power supply
and MUST be protected by the safety devices required by
the applicable legislation.
CAUTION
To guarantee the unit is completely earthed, always
connect the booster heater power supply and the earth
cable.
INFORMATION
The non-self-resetting thermal cut-out of the booster heater
is set below 89°C.
Make sure that the power supply is in accordance with the booster
heater capacity, as listed in the table below.
Booster heater
Power supply
capacity
2.4 kW
1~ 230 V
1 Connect the booster heater power supply cable to the
appropriate terminals as shown in the illustration below.
F2B
L N
L N
2 Fix the cable with cable ties to the cable tie mountings.
7.10
Finishing the outdoor unit
installation
7.10.1

To finish the outdoor unit installation

1 Insulate and fix the refrigerant piping and interconnection cable
as follows:
c
a
d
b
e
f
a
Gas pipe
b
Gas pipe insulation
c
Interconnection cable
d
Liquid pipe
e
Liquid pipe insulation
f
Finishing tape
2 Install the service cover.
7.10.2

To close the outdoor unit

1 Close the switch box cover.
Installer reference guide
48
2 Close the service cover.
7.11
7.11.1
1 Make sure that the front panel is removed from the indoor unit.
2 Plug the user interface cover into the hinges.
Maximum running
current
11 A
3 Mount the front panel to the indoor unit.
7.11.2
1 Close the switch box cover.
2 Reinstall the top plate.
3 Reinstall the front panel.
8
8.1
This chapter describes what you have to do and know to configure
the system after it is installed.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following:
▪ The calculations of the software
▪ What you can see on and do with the user interface
How
You can configure the system using two different methods.
NOTICE
When closing the outdoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
Finishing the indoor unit
installation
To fix the user interface cover to the
indoor unit
See
"7.2.3 To open the indoor unit" on

To close the indoor unit

NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
Configuration

Overview: Configuration

ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
page 30.