4 About the units and options
4.2

Identification

NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1

Identification label: Outdoor unit

Location
Model identification
Example: ER L Q 006 CA V3
Code
ER
European split outdoor pair heat pump
L
Low water temperature – ambient zone: −10~
−20°C
Q
Refrigerant R410A
006
Capacity class
CA
Model series
V3
Power supply
4.2.2

Identification label: Indoor unit

Location
Model identification
Example: E HV H 04 SU 18 CB 6W
Code
E
European model
HV
Floor-standing indoor unit with integrated tank
H
Heating only
04
Capacity class
SU
Integrated tank material: Stainless steel
Model compatible with the G3 Building
Regulations in the UK.
Installer reference guide
10
Explanation
Description
Code
18
Integrated tank volume
CB
Model series
6W
Backup heater model
4.3

Combining units and options

4.3.1

Possible options for the outdoor unit

Drain pan (EKDP008CA)
The drain pan is required to gather the drain from the outdoor unit.
The drain pan kit consists of:
▪ Drain pan
▪ Installation brackets
For installation instructions, see the installation manual of the drain
pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain
pan.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the drain
pan heater.
INFORMATION
In case the drain pan heater is used, the jumper JP_DP on
the service PCB on the outdoor unit MUST be cut.
After cutting the jumper, you MUST reset the outdoor unit
to activate this function.
U-beams (EKFT008CA)
The U-beams are installation brackets on which the outdoor unit can
be installed.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the
outdoor unit.
Low sound cover (EKLN08A1)
In sound sensitive areas (e.g. near a bedroom), you can install the
low sound cover to decrease the operation noise of the outdoor unit.
You can install the low sound cover:
▪ On mounting feet to the ground. This must withstand 200 kg.
▪ On brackets to the wall. This must withstand 200 kg.
If you install the low sound cover, you also need to install one of the
following options:
▪ Recommended: Drain pan kit (with or without drain pan heater)
▪ U-beams
For installation instructions, see the installation manual of the low
sound cover.
4.3.2

Possible options for the indoor unit

Domestic hot water tank kit (EKVSU180+260A)
The domestic hot water tank kit makes it easier to comply with
section G3 of the Building Regulations in the UK. It contains the
following components:
▪ Pressure relief valve
▪ Pressure reducing valve
▪ Expansion vessels (1 and 2)
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Description
Daikin Altherma – Low temperature split
4P449978-1B – 2018.07