7 Installation
b
(mm)
a
Maximum snowfall height
b
EKFT008CA option kit
Installer reference guide
32
INFORMATION
If you install the U-beams in combination with the low
sound cover (EKLN08A1), different installation instructions
apply for the U-beams. See the installation manual of the
low sound cover.
a
a Low sound cover
b Bottom parts of the low sound cover
c U-beams
7.3.4

To install the outdoor unit

CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1 Lift the outdoor unit as described in
accessories from the outdoor unit" on
2 Install the outdoor unit as follows:
a
1
a
Air outlet
NOTICE
The pedestal MUST be aligned with the backside of the
U‑beam.
3 Remove the protective cardboard and instruction sheet.
b
a
a
Protective cardboard
b
Instruction sheet
ERLQ004~008CA + EHVH04+08SU18+26CB6W
"3.2.2  To remove the
page 8.
a
2
Daikin Altherma – Low temperature split
4P449978-1B – 2018.07