9.1 Functional data
Variable
Input resistance R
for E
for E
for E
for E
for E
for E
Output resistance R
for E
for E
for E
for E
for E
Insulation resistance R
for E
for E
for E
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection acc. to EN 60 529, IEC 60529
Maximum tightening torque for fixing screws
for E
for E
for E
for E
Cable connection
for E
for E
for E
9.1.17

SIWAREX WL290 DB-S CA

Table 9-18
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
68
e
= 0.06; 0.13 t
max
= 0.28 t
max
= 0.5; 1; 2; 3.5; 5; 10 t
max
= 13 t
max
= 28 t
max
= 60 t
max
a
= 0.06; 0.13; 0.28 t
max
= 0.5; 1; 2; 3.5; 5; 10 t
max
= 13 t
max
= 28 t
max
= 60 t
max
is
= 0.06; 0.13; 0.28 t
max
= 0.5; 1; 2; 3.5; 5; 10 t
max
= 13; 28; 60 t
max
tn
ts
= 0.06; 0.13; 0.28 t
max
= 0.5; 1; 2; 3.5; 5 t
max
= 10 t
max
= 13; 28; 60 t
max
= 0.06 t, 0.13 t, 0.28 t, 0.5 t, 1 t
max
= 2 t, 3.5 t, 5 t
max
= 10 t; 13 t; 28 t; 60 t
max
Technical specifications SIWAREX WL290 DB-S CA
max
tu
Operating Instructions, 04/2021, A5E02199611B-12
Value
1260 Ω ± 100 Ω
1260 Ω ± 250 Ω
1100 Ω ± 100 Ω
1200 Ω ± 100 Ω
1075 Ω ± 100 Ω
1350 Ω ± 200 Ω
1020 Ω ± 0.5 Ω
1025 Ω ± 25 Ω
1000 Ω ± 0.5 Ω
930 Ω ± 0.5 Ω
1175 Ω ± 0.5 Ω
≥ 20 MΩ
≥ 5000 MΩ
≥ 20 MΩ
- 10 ... + 40 °C
- 35 ... + 70 °C
- 50 ... + 90 °C
Stainless steel, mat. no. 1.4542
IP66 and IP68
8 Nm
14 Nm
10 Nm
-
Four-core, shielded PU cable
3 m
6 m
15 m
Value
WL290
DB-S CA
Double cutter
Container scales on vehicles, platform
scales and silo scales
2.3; 4.5; 9.1; 13.6; 18; 23; 27; 34; 45; 68;
91; 113 t
C3 for 2.3; 4.5; 9.1; 13.6; 18; 23; 27; 34;
45; 68; 91; 113 t
C4 for 2.3; 4.5; 9.1 t
SIWAREX WL200