Prior to Installation:
•
Make sure you have all necessary parts by checking the diagram and parts list. If
any part is missing or damaged, please contact Kraus Customer Service at 800-
1 15/16"
∅
775-0703 for a replacement
(
50mm)
∅
•
1 3/4"
Turn off the hot and cold water supply at the angle stops and turn on the old
∅
(
45mm)
∅
faucet to release any built up pressure. Remove existing faucet. Clean sink or
countertop to remove any debris, plumber's putty, or silicone
1 15/16"
∅
(
50mm)
•
∅
Place bucket under angle stops. Turn on to flush any debris prior to installing new
plumbing. Shut off angle stops
•
Pre-drilled hole size requirement: 1-3/8" (min) – 1-1/2" (max)
•
Max countertop thickness without deck plate: 1-1/2"
•
Max countertop thickness with deck plate: 1"
9/16"-18UNEF
Tools you will need:
B
Adjustable Wrench
G
19.7
º
10 1/8"
(257mm)
Without deck plate:
1/16" (1mm) min.
1-1/2" (38 mm) max.
Ø 1-3/8" (35 mm) min.
Ø 1-1/2" (38 mm) max.
With deck plate:
1/16" (1mm) min.
1" (25.4 mm) max.
Ø 1-3/8" (35 mm) min.
Ø 1-1/2" (38 mm) max.
2
G
Safety Goggles
G
F
E
E
7/8"
(22mm)
8 5/16"
(21mm)
1 3/8"
(35mm)
1 1/4-18UNF-2A
Bucket
G
G
F
F
1A
Tools You Will Need
Adjustable wrench
3
Silicone Sealant
Silicone Sealant
D
D
Half Moon Locking Nuts
B
2
J