Advertisement

Quick Links

ArtNet PixxControl PX2
User manual
Art-Net™ Designed by and Copyright Alderamin Group Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ArtNet PixxControl PX2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DMX4ALL ArtNet PixxControl PX2

  • Page 1 ArtNet PixxControl PX2 User manual Art-Net™ Designed by and Copyright Alderamin Group Ltd.
  • Page 2: Table Of Contents

    ArtNet PixxControl PX2 For your own safety, please read this user manual and warnings carefully before installation. Content Description ........................3 Data sheet ........................5 Content ........................5 Modell Overview ......................6 Connection ......................... 7 Connection of digital LEDs with one control signal (DATA) ........7 Connection of digital LEDs with two control signals (CLK+DATA) ......
  • Page 3: Description

    CTRL output The CTRL output can be used to switch off the power supply for the LED installation after 5 minutes as soon as the ArtNet PixxControl PX2 doesn’t receive data anymore or the connected digital LEDs don’t light up.
  • Page 4 Android app. This allows the network settings of the PC or Android device to remain unchanged in order to configure the IP of the ArtNet PixxControl PX2. Important parameters such as the pixel type, the pixel group size or the color sequence can be set individually via RDM for both outputs.
  • Page 5: Data Sheet

    ArtNet PixxControl PX2 Data sheet Power supply: 8-24V DC (150mA @ 12V / 100mA @ 24V) Connection: RJ45 Ethernet 12 screw terminal Ethernet: 10 Mbit/s | 100 Mbit/s Protocol: ArtNet Output protocol: APA-101, APA-104, APA-102, DycoLED PB3, DycoLED PB5, GS8208,...
  • Page 6: Modell Overview

    UCS1903, UCS1912, UCS2903, UCS2912, UCS9812 WS2801, WS2811, WS2812(B), WS2813, WS2815, WS2818, WS2821 RGB (sequence settable) SingleColor white SingleColor red Color sequence SingleColor green SingleColor blue RGBW Configuration Web-Interface / RDM / DMX4ALL Commands   Not available in this version Available in this version...
  • Page 7: Connection

    ArtNet PixxControl PX2 Connection Connect digital LEDs with one control signal (DATA) For digital LEDs with one control signal only DATA and GND must be connected (e.g. WS2811 / SK6812 / APA-104 / TM1804). The data line should not be longer than 1m.
  • Page 8: Connection Of Digital Leds With Two Control Signals (Clk+Data)

    ArtNet PixxControl PX2 Connect digital LEDs with two control signals (CLK+DATA) For digital LEDs with two control signals DATA, CLK and GND must be connected (e.g. WS2801 / APA-102 / SK9822). The data line should not be longer than 1m.
  • Page 9: Connect Dmx Devices

    ArtNet PixxControl PX2 Connect DMX Devices Each port at the ArtNet PixxControl PX2 can also be configured as DMX output. Thus, two DMX universes can be output via ArtNet.  Et hernet ArtNet PixxControl PX2 PO WER SUPPLY DMX512 DMX512...
  • Page 10: Connect Digital Leds Of Several Types

    ArtNet PixxControl PX2 Connect digital LEDs of several types On the ArtNet PixxControl PX2 each port is adjustable individually. So, it is possible to connect two different types of digital LEDs with different control protocols. Et hernet ArtNet PixxControl PX2...
  • Page 11: Connect Digital Leds And Dmx

    ArtNet PixxControl PX2 Connect digital LEDs and DMX At the ArtNet PixxControl PX2 each port is configurable individually. So, it is possible to connect digital LEDs to one output and use the other output to output a DMX512 signal. ...
  • Page 12: Ctrl Output

    ArtNet PixxControl PX2 CTRL Output The ArtNet PixxControl PX2 has a CTRL control output that can switch off the load power supplies for the LED installation to avoid power loss for power supplies that are not needed for a longer period of time.
  • Page 13: Connection With Long Data Lines

    ArtNet PixxControl PX2 Connection with long data lines For longer data lines (more than 1m) and by using digital LED stripes, the use of a PixxRangeExtender is recommended to prepare the control signal and isolate the individual areas. In this case, the PixxRangeExtender is connected directly in front of the signal input of the digital LED strip.
  • Page 14: Power Supply Digital Led-Stripes

    ArtNet PixxControl PX2 Power supply digital LED-Stripes Generally digital LED-Stripes are operated with a power supply of 5V. Relatively high currents for the complete installation are the result. A voltage drop occurs on the digital LED-Stripe itself, so little by little the brightness reduces.
  • Page 15: Voltage Monitoring

    ArtNet PixxControl PX2 Voltage Monitoring The ArtNet PixxControl PX2 can monitor the power supply of the connected LED strips. For this, the operating voltage of the LED strip must be connected to the ArtNet PixxControl PX2 in addition to the control signal.
  • Page 16: Led Display

    ArtNet PixxControl PX2 LED Display The ArtNet PixxControl PX2 has several display status LEDs. A green and a yellow LED on the Ethernet port, showing the network activity. Furthermore, a RGB-LED signals the device status. Green Ethernet-LED Power supply not connected /...
  • Page 17: Device Settings With Web-Interface

    Set IP via IP-Configurator The IP Configurator allows setting the IP address and the Netmask even if the network setting of the PC is not in the IP range of the ArtNet PixxControl PX2. Install the IP-Configurator Connect the ArtNet PixxControl PX2 with the network and turn it on...
  • Page 18: Set Ip Of The Pc

    ArtNet PixxControl PX2 Set IP of the PC Within the delivery state of the ArtNet PixxControl PX2, the assigned IP-Address is 2.0.0.10 used for the web interface. Set the computers network card to this IP range, to access the IP address 2.0.0.10 via a web browser.
  • Page 19: Device Settings

    ArtNet PixxControl PX2 Device Settings To get the following configuration page, the IP of the ArtNet PixxControl PX2 must be called up via a web browser in the address bar (delivery state: 2.0.0.10): DHCP-Mode: With the DHCP mode setting, DHCP can be activated (enable) or deactivated (disable) for the ArtNet PixxControl PX2.
  • Page 20 The protocol of the DMX4ALL commands with which the control of the ArtNet PixxControl PX2 is possible, can be switched between TCP and UDP. With the input field "Port" the receive port for the DMX4ALL commands is configured. A change of this parameter needs a restart of the device.
  • Page 21: Output Settings

    ArtNet PixxControl PX2 Output settings The Output 1 and Output 2 pages are used to change the settings for Output 1 respectively Output 2. ArtNet Parameter Up to 8 ArtNet universes can be output with each of the two data outputs.
  • Page 22 ArtNet PixxControl PX2 1st Uni Start Ch Under 1st Uni Start Ch the start channel of the first universe can be defined, from which the output of the data on the outputs takes place. Thus it is possible to select the first control channel of the output freely, within the first universe.
  • Page 23 ArtNet PixxControl PX2 Master-Brightness Red/Green/Blue/White defines the master brightness separately for the colors red, green, blue and white. (Available for TM1814) Pixel Count The input field Pixel Count can be used to set how many digital LEDs are controlled with the data signal of the output.
  • Page 24: Login For Web-Interface

    ArtNet PixxControl PX2 Login for Web-Interface The ArtNet PixxControl PX2 offers the option to create a login for the web interface. A password can be named on the service site under login options. An empty password allows the access without password request.
  • Page 25: Pixel Assignment

    Pixel Assignment 8-Bit Control The ArtNet PixxControl PX2 controls up to 130RGB pixel. For this up to 8 ArtNet universes are used. With 8-bit control, one channel is used for R, one channel for G and one channel for B, which results in a maximum of 170 RGB pixels per universe.
  • Page 26 ArtNet PixxControl PX2 16-Bit Control The 16-bit control is available for LED types with more than 8 bits. These are the LPD1886 with 12 bit and the UCS9812 with 16 bit. In the 16-bit control always 2 DMX channels are used for one color control.
  • Page 27: Check Connected Leds

    By clicking the button, the LEDs on output 1 respectively output 2 are controlled in the selected color. For the Test Output no control signal is to send to the ArtNet PixxControl PX2! An external control signal always has priority over a test output.
  • Page 28: Rdm

    ArtNet PixxControl PX2 RDM is the short form for Remote Device Management. The ArtNet PixxControl PX2 provides the RDM functionality via the ArtNet interface. Device information and settings can be read or set. A direct access to the device is not necessary.
  • Page 29 ArtNet PixxControl PX2 Parameter ID Discovery ANSI/ Command Command Command PID:  SERIAL_NUMBER 0xD400 PID:   DISPLAY_AUTO_OFF 0xD401 PID:   PIXEL_TYPE 0xD410 PID:   GROUP_SIZE 0xD412 PID:   COLOR_SEQUENCE 0xD413 1) Manufacturer depending RDM control commands (MSC – Manufacturer Specific Type)
  • Page 30 ArtNet PixxControl PX2 PIXEL_TYPE PID: 0xD410 Sets the used LED-Pixel-Type. Send: PDL=0 Receive: PDL=1 (1 Byte PIXEL_TYPE_ID) Send: PDL=1 (1 Byte PIXEL_TYPE_ID) Receive: PDL=0 PIXEL_TYPE_ID Function DycoLED PB3 TM1804 WS2801 WS2811 LPD8806 UCS1903 / UCS1912 APA-102 TM1812 LPD1886 8Bit LPD1886 12Bit (8bit controlled)
  • Page 31 ArtNet PixxControl PX2 GROUP_SIZE PID: 0xD412 Sets the size of the pixel group. Send: PDL=0 Receive: PDL=1 (1 Byte pixel group size) Send: PDL=1 (1 Byte pixel group size) Receive: PDL=0 Parameter Function 1-127 Pixel group size COLOR_SEQUENCE PID: 0xD413 Sets the used color sequence.
  • Page 32: Dmx4All-Command Interface

    DMX4ALL-Command Interface The ArtNet PixxControl PX2 has a further communication interface, using DMX4ALL-Commands. Please take a look in the separate DMX4ALL Command description for the possible DMX4ALL-Commands. The settings are to be made in the Main Settings under DMX4ALL Command Options.
  • Page 33: Factory Reset

    ArtNet PixxControl PX2 Factory Reset To reset the ArtNet PixxControl PX2 to the delivery state, proceed as follows: To get the delivery status via web browser please proceed as follows: Open service site in web browser Enter the service code „7319“ into input field...
  • Page 34: Firmware-Update

    ArtNet PixxControl PX2 Firmware-Update The ArtNet PixxControl PX2 has an update function which allows to transfer further firmware versions. Proceed as follows: Start the update software DMX4ALL LAN-Updater Click FIND, if device is not shown in the list Chose ArtNet PixxControl PX2 from list Click Firmware-Update Chose and confirm firmware file (.bin)
  • Page 35: Dimension

    ArtNet PixxControl PX2 Dimension All details in mm...
  • Page 36: Accessories

    ArtNet PixxControl PX2 Accessories Top hat rail mounting 700 Wall bracket for top hat rail housing Power supply 12V...
  • Page 37: Ce-Conformity

    ArtNet PixxControl PX2 CE-Conformity This assembly (board) is controlled by a microprocessor and uses high frequency. In order to maintain the properties of the module with regard to CE conformity, installation into a closed metal housing in accordance with the EMC directive 2014/30/EU is necessary.
  • Page 38: Risk-Notes

    ArtNet PixxControl PX2 Risk-Notes You purchased a technical product. Conformable to the best available technology the following risks should not excluded: Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary.
  • Page 39 Germany Last changes: 28.06.2023 © Copyright DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems.

This manual is also suitable for:

Artnet pixxcontrol px1

Table of Contents