Dimplex purifire DF3220 Sseries Practical User's Manual page 12

Advertisement

UPPER LIGHT BULB REQUIREMENTS
Quantity of 2 clear chandelier or candelabra bulbs with an E-14 (small) socket base, 25 watt rating.
DO NOT EXCEED 25 WATTS PER BULB
TO ACCESS THE UPPER LIGHT BULB AREA:
1. Open the bi-fold doors.
2. Remove upper light bracket with a
screwdriver.
3. Replace bulb.
4. Reassemble in the reverse order
as above.
PURIFIRE™ FILTER
The Purifi re™ fi lter supplied in your fi replace is reusable and washable. The fi lter should be cleaned or
replaced on average once a year. To clean the fi lter gently tap fi lter on a hard surface to dislodge any
loose dirt or debris, and then clean with water. No soap or cleaning products are recommended. The
fi lter size is 508mm (20") X 244mm (10") X 25mm (1") rated at MERV 10. If using an after market fi lter
follow the manufacturers recommended replacement instructions.
TO REPLACE FILTER:
1. Open the bi-fold doors.
2. Remove the 3 mounting screws from the air fi lter bracket.
3. Remove the air fi lter bracket assembly from the fi rebox.
4. Slide fi lter out of air fi lter bracket.
5. Reassemble in reverse order as above.
NOTE
If after market air fi lter is used ensure it is installed according to the manufacturers recommended
instructions.
FIGURE 11
Air Filter
Bracket
Mounting Screws
FIGURE 10
Air Filter
Upper Light
Screw
Upper Light
Bracket
10