Harvia K10G Instructions For Installation And Use Manual

Harvia K10G Instructions For Installation And Use Manual

Electric sauna heater

Advertisement

Quick Links

K10G, K12G, K15G
Instructions for Installation and Use of Electric Sauna Heater
EN
K10G, K12G, K15G
20032023 / Y05-0937 B

Advertisement

Table of Contents
loading

Summary of Contents for Harvia K10G

  • Page 1 K10G, K12G, K15G Instructions for Installation and Use of Electric Sauna Heater K10G, K12G, K15G 20032023 / Y05-0937 B...
  • Page 2: Table Of Contents

    Purpose of the electric heater: The KG-heaters are designed for the heating of large saunas to bathing tempera ture. It is forbidden to use the heater for any other purposes. • The guarantee period for heaters and control equipment used in saunas by families is two (2) years.
  • Page 3: Instructions For Use

    1. INSTRUCTIONS FOR USE 1.1. Piling of the Sauna Stones The sauna stones for an electric heater should be 5–10 cm in diameter. The heater stones should be solid blocks of stone specially intended for use in the heater. Neither light, porous ceramic “stones“ of the same size nor soft potstones should be used in the heater, because they may cause the resistance temperature to rise too high as a result of which the...
  • Page 4: Sauna Water

    Staying in the hot sauna for long periods of time Do not force other bathers from the sauna by • makes the body temperature rise, which may be throwing excessive amounts of water on the stones. dangerous. The maximum volume of the ladle is 0.2 litres. Forget all your troubles and relax.
  • Page 5: The Sauna Room

    2. THE SAUNA ROOM 2.1. Insulation and Wall Materials of the temperature allowed in the wall and ceiling surfaces Sauna Room of the sauna room is +140 degrees Celsius. In an electrically heated sauna, all the massive wall Sauna heaters equipped with CE signs meet all surfaces which store plenty of heat (such as bricks, of the regulations for sauna installations.
  • Page 6: Hygienic Conditions Of The Sauna Room

    be followed when arranging ventilation. It is advisable to vacuum or sweep the sauna room The series of pictures shows examples of ventila- floor regularly. In addition, the floor may be wiped tion systems for a sauna room. See fig. 2. with a damp cloth.
  • Page 7: Electric Heater Insulation Resistance

    Fuses [A] 200 VAC Heater Output Saunaroom Min. distances Cubic vol. Height 3-Phase min. max. min. min. min. max. See item 2.3. See fig. 3. K10G 10,0 1900 1200 3x30 K12G 12,5 2100 1400 3x40 K15G 15,0 2100 1400 3x45 Model and...
  • Page 8: Spare Parts

    We recommend to use only the manufacturer’s spare parts. K10G, K12G, K15G GLOBAL: P.O.Box 12 | Teollisuustie 1-7 | 40951 Muurame | FINLAND | +358 207 464 000 | harvia@harvia.fi | www.harvia.com CENTRAL EUROPE: Sentiotec GmbH | Division of Harvia Group | Wartenburger Straße 31, A-4840 Vöcklabruck...

This manual is also suitable for:

K12gK15g

Table of Contents