Installing A Camera Directly To An Indoor Wall; Installation Requirements; Preparing The Wall For Installation; Installing The Wall Mount - Bosch NDP-45A2-Z12C Installation Manual

Table of Contents

Advertisement

26
en | Installing a Camera Directly to an Indoor Wall
10

Installing a Camera Directly to an Indoor Wall

10.1

Installation Requirements

10.2

Preparing the Wall for Installation

Notice!
Indoor use only!
The instructions in this chapter apply to indoor installation only. For outdoor installation, use
either the surveillance cabinet (NDA-U-PAx) or the mount plate (NDA-U-WMP).
1.
2.
3.
4.
5.
10.3

Installing the Wall Mount

1.
2.
Ensure that the cables are long enough to reach through the mount and the camera's
mounting cap to the connections from the camera.
1.
2.
3.
10.4

Attaching the Camera to the Pendant Interface Plate

1.
2.
3.
2020-05 | 2.0 |
The wall is thick enough to install the mounting screws.
The wall can sustain at least eight (8) times the weight of the camera (1.88 kg (4.14 lb)):
> 15 kg (33 lb).
Determine a secure location for the wall mount. Ensure there is an adequate opening in
the wall for the cables to pass through.
Use the direct connect plate as a template to mark the location to drill holes for the four
mounting screws (and anchors (user-supplied) if necessary), and to cut the hole for the
cables.
Drill the holes.
Insert the wall anchors (user-supplied) (if necessary) into the wall at the locations
marked in step 2.
Cut an appropriately-sized hole for the cables, using a drywall utility saw or jig saw.
Attach the direct connect plate to the wall.
Thread the RJ45 cable and 24 VAC cables through the wall and then through the
(adapter).
Slide the mounting flange over the wall mount.
Attach the wall mount to the mounting flange and to the direct connect plate using four
M5 screws.
Attach the wall mount to the mounting flange and fix them on the front door of the Wall-
mount Surveillance Cabinet by using four M5 screws.
Install the pendant interface plate mount onto the end of the wall mount or the pipe
mount.
Attach an M5 screw and the L-shaped end of the safety tether to the stand-off on the
pendant interface plate mount with the T25 Torx screwdriver.
Attach the M4 screw to the ground point on the pendant interface plate mount with the
T25 Torx screwdriver.
Installation Manual
AUTODOME IP 4000i
Bosch Security Systems

Advertisement

Table of Contents
loading

Table of Contents