Daikin Altherma ERGA04E V3 Series Installer's Reference Manual page 287

Table of Contents

Advertisement

Field settings table
Breadcrumb Field code
Setting name
9.1
Schedule
9.1
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
9.1
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
9.1
[0-02]
High ambient temp. for LWT add zone heating WD curve.
9.1
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
9.1
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
9.1
[0-05]
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
9.1
[0-06]
High ambient temp. for LWT add zone cooling WD curve.
9.1
[0-07]
Low ambient temp. for LWT add zone cooling WD curve.
└─ Tank
9.1
[6-0D]
Heat up mode
9.1
[6-0A]
Comfort setpoint
9.1
[6-0B]
Eco setpoint
9.1
[6-0C]
Reheat setpoint
└─ Domestic hot water
9.2.1
[E-05]
Domestic hot water
[E-06]
[E-07]
9.2.2
[D-02]
DHW pump
9.2.4
[D-07]
Solar
└─ Back up heater
9.3.1
[E-03]
BUH type
9.3.2
[5-0D]
Voltage
9.3.3
[4-0A]
Configuration
9.3.4
[6-03]
Capacity step 1
9.3.5
[6-04]
Additional capacity step 2
9.3.6
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.3.7
[5-01]
Equilibrium temperature
9.3.8
[4-00]
Operation
└─ Booster heater
9.4.1
[6-02]
Capacity
9.4.3
[8-03]
BSH eco timer
9.4.4
[4-03]
Operation
└─ Emergency
9.5.1
[4-06]
Emergency
9.5.2
[7-06]
Compressor forced off
└─ Balancing
9.6.1
[5-02]
Space heating priority
9.6.2
[5-03]
Priority temperature
9.6.3
[5-04]
Offset BSH setpoint
9.6.4
[8-02]
Anti-recycle timer
9.6.5
[8-00]
Minimum running timer
9.6.6
[8-01]
Maximum running timer
9.6.7
[8-04]
Additional timer
Installer settings
9.7
[4-04]
Water pipe freeze prevention
(*1) *3V*_(*2) *6V*_(*3) *9W*_
(*4) EHB*_(*5) EHV*_
(*6) *X*_(*7) *H*
Range, step
Default value
R/W
0: No
1: Yes
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
[9-05]~[9-06]°C, step: 1°C
50°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
R/W
25~43°C, step: 1°C
35°C
R/W
10~25°C, step: 1°C
20°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: No DHW (*4)
2: EKHW (*4)
3: Integrated (*5)
7: EKHWP (*4)
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
R/W
0: No
1: Yes
R/O
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
R/W (*2)
0: 230V, 1~ (*1) (*2)
R/O (*1)
1: 230V, 3~ (*2)
(*3)
2: 400V, 3~ (*3)
R/W
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emergency
R/W
0~10kW, step: 0,2kW
2kW (*2)
3kW (*1)(*3)
R/O (*1)
0~10kW, step: 0,2kW
R/W (*2)
0kW (*1)
(*3)
4kW (*2)
6kW (*3)
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0~10kW, step: 0,2kW
3kW (*4)
0kW (*5)
R/W
20~95 min, step: 5 min
50 min
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
R/W
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
R/W
0: Disabled
1: Enabled
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour [E-07]≠1
R/W
0~20 min, step 1 min
1 min
R/W
5~95 min, step: 5 min
30 min
R/W
0~95 min, step: 5 min
95 min
0: Intermittent
1: Continuous
2: Off
5/11
Installer setting at variance with
default value
Date
Value
4P629091-1C - 2022.08

Advertisement

Table of Contents
loading

Table of Contents