Nuvico HDoCS DT-P1620 Setup Manual page 24

Table of Contents

Advertisement

Setup Guide of HDoCS Digital Video Recorder
Setting Sensor Alarms
.
Purpose:
Set up handling method of an external sensor alarm.
Steps:
3. Enter Alarm Settings of System Configuration and select an alarm input.
Menu> Configuration> Alarm
Select Alarm Input tab to enter Alarm Input Settings interface.
Alarm Status Interface of System Configuration
4. Set the handling method of the selected alarm input.
Check the Setting checkbox and click
5. Select Trigger Channel tab and select one or more channels which will start to record or become
full-screen monitoring when an external alarm input is triggered.
6. Select Arming Schedule tab to set the channel's arming schedule.
Choose one day of a week and Max. eight time periods can be set within each day.
Time periods shall not be repeated or overlapped.
button to set its alarm response actions.